7 - MECHANICAL PRESSURE RELEASE BUTTON: if required, by
pressing hard on the mechanical pressure release button,
the oil can be returned to the reservoir at any time, regard-
less of the status of the battery.
8 - GROUNDING SOCKET + KNOB: for connecting a Cembre
grounding cable. Should there be the danger of voltage
gradients between cutting head and pump, the pump can
be connected to earth using the earth terminal and the
specific cable so as to form an equipotential connection.
This grounding device is available as an optional accessory (Part. no EK 100).
One end of the ground cable must be connected to the earth terminal of the pump, the other end
must be connected to a suitable item within the vicinity of the pump (e.g. grate, steel sheet, etc.).
9 - I38F AUTOMATIC QUICK COUPLER: enables connection of the insulated flexible hose.
The swivel attachment enables the rotation of the hose to the most convenient position
for the operator.
In order to attach or disconnect the hose, pull the ring back.
The couplers cannot be disconnected if the system is under pressure.
The anti-dust protection cap must be used on both the hose and pump couplings to prevent
ingress of dirt or contamination.
10 - CAPACITIVE TOUCH BUTTON: for menu selection allows selection of various screens only
when the display is on (Ref. to section 7).
Do not apply pressure to or stab at the touch button, a light touch using a bare finger
is sufficient. The command pulse is sent when the finger releases the button.
The capacitive touch button may not work if touched using objects or when wearing
gloves, therefore always operate it using a bare finger.
11 - OLED DISPLAY: switches on when the control button (12) on the pump is pressed forward
and off automatically after 1 hour of non-operation.
12 - CONTROL BUTTON: rocker type, push forward once to wake
up the pump and turn on the display.
NOTE: if required the control button can be used to activate
the pump motor or release the oil in manual mode instead
of the RRC1 radio remote control.
By default setting this function is disabled, to enable refer
to section 7.4.
13 - HANDLE: for safe and balanced transportation of the pump.