[Detection Mode] (Default: Outdoor mode)
Outdoor mode
This option is for general outdoor applications. As required, select the Vertical or Horizontal setting,
and then set any additional settings.
Outdoor Fence/Wall top protection mode
Select this mode if you want to detect a person trying to climb over a fence with the REDSCAN unit
installed in a general outdoor environment. This mode is available only if it is installed horizontally.
Outdoor Loitering detection mode (version 8.0.0 or later)
Select this mode if you want to detect loitering object within the detection zone in general outdoor
environment.
Indoor Mode
For general indoor applications, e.g. warehouse, this option can be selected. In this mode,
Environmental Resistance and DQ Output are disabled.
Indoor Fence/Wall top protection mode
Select this mode if you want to detect a person trying to climb over a fence in indoor environment.
Indoor Loitering detection mode (version 8.0.0 or later)
Select this mode if you want to detect loitering object in indoor environment.
[Detection Area] (Default: H2)
There are 2 options, Horizontal Detection Area 2 and Vertical Detection Area.
H2 (Horizontal Detection Area 2)
This mode allows setting of a fan-like detection area in the horizontal direction with a maximum radius
of 30 m (Approx. 100 ft.), a spread angle of 190 degrees.
This mode detects intrusion into the detection area from any direction.
The Redscan will generate the alarm output 1 minute (variable) after the initial detection, so long as
the detected object stays in the detection area.