Command Types and Responses
Subcommand Format
Subcommand Response
Format

4-4-12 Auto Command Processing Cancel (AA)

Command Format
52
Unit
@
No.
00 to 31
Header PW
Unit
@
P
W
No.
Header PW
Auto command processing is cancelled, and the command wait status is
restored.
Unit
@
A
No.
00 to 31
Header AA
W C/E ×
P
FCS
R/W Head No. (1 to 4)
Specifies cancel or inquiry of
polling auto processing results
C: Processing result inquiry
E: Cancel
7
4
FCS
*
CR
End code
00: At normal end
74: DC not close (after second pass)
75: Polling auto processing canceled (before
communications processing with DC)
76: Polling auto processing canceled (the DC
approaches, and processing is canceled
during communications processing with the
DC and after completion of processing)
A
FCS
*
CR
Section 4-4
*