Saluki SPS8 Series User Manual page 36

Programmable dc power supply
Table of Contents

Advertisement

Tel: 886.909 602 109 Email: sales@salukitec.com
www.salukitec.com
Unit: A
Return command: none
Example:
1) Sending command [:]CURR 3, it means to set the current value as 3A.
2) Sending command [:]CURR MAX
Providing the maximum setup current value of the power supply is 2.0000A, it means to set the present current
value as the maximum current value 2.0000A.
3) Command sent [:]CURR MIN
Providing the current minimum setup current is 0.0000A, it means to set the present current as the minimum
current 0.0000 A.
2.Related Command
[:]CURR? MAX|MIN, the command used to query the setup current value, the
maximum setup current value and the minimum setup current value
Return command parameters: numerical value
Example:
1) If you want to query the setup current value, please send command [:]CURR?, if the return command is
1.0000,it means the setup current of power supply is 1.0000A.
2) If you want to query the maximum setup current value, please send command [:]CURR? MAX, if the return
command is 2.0000, it means the maximum setup current value of power supply is 2.0000A.
3) If you want to query the minimum setup current value, please send command [:]CURR? MIN, if the return
command is 0.0000, it means the minimum setup current value of the power supply is 0.0000A.
Command [:]VOLTage:PROTection <Value>
1. This command is used to set the upper limit voltage of the power supply, namely the maximum output
voltage.
Parameters: numeric |MAX|MIN
Unit: V
Return command: none
Example:
1) If sending command [:]VOLT:PROT 30, it means to set 30.000V as the upper limit voltage of the power
supply.
2) If sending command [:]VOLT:PROT MAX, it means to set the upper limit voltage as the maximum output
voltage value of the power supply.
3) If sending command [:]VOLT:PROT MIN, it means to set the upper limit voltage as the minimum output
voltage value of the power supply.
2. Related command [:]VOLTage:PROTection? [MAX], it means to query the upper limit voltage
Return command parameters: numerical value
Example:
1)If sending command [:]VOLT:PROT?, If the return command is 20.000, it means the upper limit voltage of
36

Advertisement

Table of Contents
loading

Table of Contents