Saluki SPS8 Series User Manual page 35

Programmable dc power supply
Table of Contents

Advertisement

Parameter: mode has three following modes,
FIXed
command set mode
LIST
sequential list mode
DRM
milliohmmeter mode
Return command: None
Example:
Sending command [:]MODE LIST, the power supply is in sequential list mode.
2. Related command [:] MODE?, to query working mode of power supply.
Return command parameter: <mode>
Command [:]VOLTage <Value>
1.This command is used to set the voltage value of power supply.
Parameters: numeric |MAX|MIN
Unit: V
Return Command: None
Example:
1) Sending command [:]VOLT 30
Means to set the voltage value of the power supply is 30V.
2) Sending command [:]VOLT MAX
Providing the maximum output voltage is 76.000V, it means to set the voltage value is the maximum voltage
76.000V.
3) Sending command [:]VOLT MIN
Providing the minimum output voltage is 0.000V, it means to set the voltage value is the minimum voltage
0.000V.
2.Related Command
maximu setup voltage value and the minimum setup voltage value.
Return command parameters: numeric
Example:
1) If you want to query the setup voltage value, please send command [:]VOLT?, if the return command is
10.0000, it means the setup voltage of power supply is 10.0000V.
2) If you want to query the maximum setup voltage value, please send command [:]VOLT? MAX, if the return
command is76.0000, it means the maximum setup voltage value of power supply is 76.0000V.
3) If you want to query the minimum setup voltage value, please send command [:]VOLT? MIN, if the return
command is 0.0000, it means the minimum setup voltage value of the power supply is 0.0000V.
Command [:]CURRent <Value>
1. This command is used to set the current value.
Parameters: numeric |MAX|MIN
[:]VOLT? MAX|MIN, the command is used to query the setup voltage value, the
Tel: 886.909 602 109 Email: sales@salukitec.com
35
www.salukitec.com