6) When the VFD display shows Step 1 Time= xxxxx S, press the numeric keys to set the test duration,
followed by pressing the key
delay time is set as 25.5S, the power supply will be automatically in the pause mode and go on excuting
only when another trigger is input.
7) When the VFD display shows Step 1 Volt= xxxxx V, press the numeric keys to set the voltage, followed by
pressing the key
8) When the VFD display shows Step 1 Curr= xxxxx A, press the numeric keys to set the current, followed
by pressing the key
9) When the VFD display shows Step 1 Max= xxxxx X, press the numeric keys to set the maximum value for
the qualified test, followed by pressing the key
10) When the VFD display shows Step 1 Min= xxxxx X,press the numeric keys to set the minimum value for
the qualified test, followed by pressing the key
11) Repeat from step 5 to step 10 to set all the other steps.
12) Repeat from step 2 to step 11 to edit other automatic test files according to your need.
13) Press the key▼ to select the item Load Atest File, followed by pressing the key
14) Then the intrument enter into the automatic test mode, showing AUT1 at the right upper corner of the VFD
display and OFF at the right lower corner of the VFD display. That means to wait for a trigger.
15) There are three trigger modes for automatic test
Press the key On/Off to trigger.
Press the key Shift+3 to trigger.
Become the high voltage level to the low voltage level by Trig_in at the rear panel and last more than
5mS.
16) When the power supply is having the automatic test, the word Wait will be showed at the right lower
corner of the VFD display. When in pause mode, the word Stay will be showed at the right lower corner of
the VFD display. When one test is finished, the test result Pass or Fail will be showed at the right lower
corner of the VFD display.
17) When one test is finished, users can press the up-down keys to make one single step worked manually. At
the moment, step n will be showed on the VFD display, indicating the step which is working; then Han is
showed, indicating that the instrument is in hand-operated single step test state, followed by the test results
being showed at the right lower corner of the VFD display.

4.7 Output On-Off Operation

When in front-panel operation, you can press the key
does not affect the present setting values. When the TRI is enable, the key
in OFF state, the TRI can be used to switch the OFF/ON state.
to confirm. Please note that the duration range is 0.2S-25.5S. If
to confirm.
to confirm.