How To Adjust The Carrying Handle; How To Rackmount The Instrument - Saluki SPS8 Series User Manual

Programmable dc power supply
Table of Contents

Advertisement

Model
SPS811
SPS812
SPS813
SPS831
SPS851
SPS852
SPS853
SPS871
SPS872
SPS873
SPS874
4. How to replace the power-line fuse
Open the plastic cover which locates at below the power input socket in the rear panel of the power supply by
screwdriver, then you will see the fuse. Please replace the damaged fuse with the matched fuse.

3.4 How to Adjust the Carrying Handle

To adjust the position, grasp the handle by the sides and pull outward. Then, rotate the handle to the desired
position. There are following three positions for you to choose:

3.5 How to Rackmount the Instrument

The power supply can be mounted in a standard 19-inch rack cabinet and be easily applied to your testing
system. If you want to rackmount the SPS8 series, please buy M151 rack kit.
Fuse Description (110VAC)
T5A 250V
T5A 250V
T5A 250V
T5A 250V
T10A 250V
T10A 250V
T10A 250V
T15A 250V
T15A 250V
T15A 250V
T15A 250V
Diagram 3.3 SPS8 series Power Supply Viewing Positions
Tel: 886.909 602 109 Email: sales@salukitec.com
Fuse Description (220VAC)
14
www.salukitec.com
T3.15A 250V
T3.15A 250V
T3.15A 250V
T3.15A 250V
T6.3A 250V
T6.3A 250V
T6.3A 250V
T10A 250V
T10A 250V
T10A 250V
T10A 250V

Advertisement