Installation

5.6 Electrical connection

DANGER
!
Risk of fatal injury due to electric shock.
Î Upon installation of the electric cables,
you are required to observe the regula-
tions concerning low-voltage installations
according to DIN VDE 0100 as well as
the regulations of your local power sup-
plier.
Î Use a suitable voltage supply which
guarantees that no dangerous voltages
reach the device in normal operation or
in the event of a fault in the system or
any other system parts.
Î Only perform the electrical connection
after switching off the supply voltage.
Make sure the supply voltage cannot be
switched on again unintentionally.
Î Use plastic cable glands with cable grip
at the cable entry.
NOTICE
!
Risk of actuator damage due to incorrect
wiring of the inputs.
Î Wire the inputs range according to the
technical data (see the 'Design and prin-
ciple of operation' section).
5-6
Wiring
Î Connect the wiring as shown in Fig. 5-5.
NOTICE
!
Risk of actuator damage due to a short cir-
cuit.
The supply voltage as well as the input and
output signals are not galvanically isolated
from one another.
Î Do not apply any external voltage.
Î Do not connect terminals with each other.
Î Make sure that the single wires of multi-
wire cables do not touch neighboring
terminals.
EB 5827-2 EN