Test operation
1. Preparation of test operation
The client approves the air conditioner.
Specify the important notes for air conditioner to the client.
2. Method of test operation
Put through the power, press ON/OFF button on the remote controller to
start operation.
Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
If the ambient temperature is lower than 16ºC, the air conditioner can't start
cooling.
Pipe expanding method
NOTE: Improper pipe expanding is the main cause of refrigerant leakage.
Please expand the pipe according to the following steps:
A: Cut the pipe
Confi rm the pipe length according to the distance of indoor unit and outdoor
unit.
Cut the required pipe with pipe cutter.
B: Remove the burrs
Remove the burrs with shaper and prevent the burrs from getting into the
pipe.
C: Put on suitable insulating pipe
pipe
pipe cut
pipe
downwards
leaning
uneven
burr
shaper
52