Page 3
Appliance filled with flammable gas R32. Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Page 5
Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
Page 6
Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
Page 7
Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
Page 8
Precautions WARNING For the air conditioner with plug ,the plug should be reachable after finishing installation For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
Precautions WARNING The air conditioner is not allowed to use in a room that has running fire (such as fire source, working coal gas ware, operating heater). It is not allowed to drill hole or burn the connection pipe. The air conditioner must be installed in a room that is larger than the minimum room area.
Page 10
MODE TURBO SLEEP I SENSE TIMER ON TIMER OFF CLOCK QUIET WIFI TEMP LIGHT air inlet Connection wire air outlet...
Page 11
MODE I SENSE TURBO SLEEP I SENSE TIMER ON TIMER OFF CLOCK QUIET WIFI TEMP LIGHT...
Page 14
This button is used for setting Fan Speed in the sequence that goes from AUTO, , then back to Auto. Auto Low speed Low-Medium speed Medium speed Note: Medium-High speed High speed It’s Low fan speed under Dry mode X-FAN function Hold fan speed button for 2s in COOL or DRY mode, the icon “ ”...
Page 16
• • • • • • • In the Cooling or Heating mode, press this button to start sleep mode. Once you set it up, this symbol “ “ appears on the screen remote control. Sleep Mode has three places to choose from, Sleep Mode 1, Sleep Mode 2, Sleep Mode 3.
Page 17
air conditioner’s temperature increases by one degree per hour in “Cooling” mode and decreases by one degree per hour in “Heating” mode. Sleep Mode 2 Sleep mode 2 “ “ will only be activated during Cooling or Heating mode. During Cooling: -If the air conditioner temperature is set between 16-23 °...
Page 18
ture will be reduced by one degree per hour in the fi rst 3 hours after activation and then will remain constant. Sleep Mode 3 Sleep Mode 3 “ “ is available in Cooling or Heating modes. By activating this function, you can create your own personalized program based on time and temperature.
Page 20
• • After starting up TIMER ON or TIMER OFF, set the constant circulating valid. After that, air conditioner will be turned on or turned off according to setting time. ON/OFF button has no effect on setting. If you don’t need this function, please use remote controller to cancel it.
Page 21
NOTE • The Quiet function can be set up in all modes; Under the Quiet mode,the fan speed is not available. • When quiet function is selected: Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or when indoor ambient temperature≤28℃, indoor fan will operate at notch 2 speed or quiet mode...
Page 25
SELF CLEAN FUNCTION Under unit off status, hold “MODE” and “FAN” buttons simultaneously for 5 seconds to turn on or off the SELF CLEAN function. When the SELF CLEAN function is turned on, indoor displays “CL”. During the SELF CLEAN process of evaporator, the unit will perform fast cooling or fast heating.
Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
Page 27
Clean and Maintenance Open panel Pull out the panel to a certain Use dust catcher or water to angle as shown in the fig. clean the filter. When the filter is very dirty, use the water (below 45 ) to clean it, and then put it in a shady and cool place to dry.
Clean and Maintenance 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Whether it's interfered severely Pull out the plug. Reinsert (such as static electricity,stable the plug after about 3min, and voltage)? then turn on the unit again.
Page 30
Malfunction analysis Power failure? Wait until power recovery. Is plug loose? Reinsert the plug. Air switch trips off or fuse is Ask professional to replace burnt out? air switch or fuse. Air condit- Wiring has malfunction? Ask professional to replace it. ioner can’t Unit has restarted immediately operate...
Page 31
Malfunction analysis Whether there’s odour source, Eliminate the odour source. Odours are such as furniture and cigarette, emitted Clean the filter. etc. Air conditioner Whether there’s interference, Disconnect power, put back operates such as thunder, wireless power, and then turn on the abnormally devices, etc.
Page 32
Malfunction analysis Error Code When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code. Error code Troubleshooting It can be eliminated after restarting the unit. If not , please It can be eliminated after restarting the unit.
Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit and air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction.
Page 36
Wall Wall Wall Wall Space Space Space Space to the to the to the to the Wall wall wall wall wall above above above above Space Wall to the Right Left Space Right Left wall to the above Rear piping hole Rear piping hole wall Rear piping hole...
Page 37
Pay attention to dust prevention and take relevant safety measures when not provided and should be bought...
Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench 1/4'' 15~20 30~40 3/8'' union nut 1/2'' 45~55 pipe 5/8'' 60~65 torque wrench 3/4'' 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
Page 39
of indoor unit and then pull it out from 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw 09K,12K, 18Κ, 24Κ Heat pump type: N(1) blue black brown yellow- green Outdoor unit connection...
Page 40
Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
Page 41
5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe capacity capacity 5000Btu/h 24000Btu/h (1465W) (7032W) 7000Btu/h 28000Btu/h (2051W) (8204W) 9000Btu/h 36000Btu/h (2637W) (10548W) 12000Btu/h 42000Btu/h (3516W) (12306W) 18000Btu/h 48000Btu/h (5274W) (14064W) After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m Additional refrigerant charging amount additional refrigerant charging amount per meter...
Configuration of connection pipe Sheet 2. Additional refrigerant charging amount for R32 Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Cooling only, cooling and Cooling only Liquid pipe Gas pipe cooling and heating heating (g / m) 1/4'' 3/8'' or 1/2'' 5/8'' or 3/4''...
Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
Page 44
Safety operation of flammable refrigerant a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding The refrigerant should be recycled into the specialized storage tank. Make sure that there isn’t any naked flame near the outlet of the vacuum pump and it’s well-ventilated.
Installation of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. installing the outdoor unit. Make sure the support can withstand at least four times of the unit weight.
Page 46
Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- 3. Pretightening the union nut with dle of outdoor unit and then remove hand. the handle. pipe joint screw union nut handle NOTE cross-hole...
Page 47
Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: Step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.
Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant charging 2. Connect the charging hose valve cap vent of piezometer to the refri- gerant charging vent of gas nut of refrigerant...
Check after installation Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed rmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage It may cause insuf cient cooling test? (heating) capacity.
Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port the distance of indoor unit and hard outdoor unit. mold expander pipe...
Page 51
Specialist’s Manual The following checks shall be applied to instal- fire extinguishing equipment shall be available to ● lations using flammable refrigerants: hand. Have a dry powder or CO fire extinguisher adjacent to the charging area. – the charge size is in accordance with the room size within which the refrigerant containing parts are in- Ventilated area ●...
Page 52
Specialist’s Manual Repair to intrinsically safe components – recovery equipment and cylinders conform to ● the appropriate standards. Do not apply any permanent inductive or capaci- d) Pump down refrigerant system, if possible. tance loads to the circuit without ensuring that this e) If a vacuum is not possible, make a manifold so will not exceed the permissible voltage and current that refrigerant can be removed from various parts...
Page 53
Specialist’s Manual dition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery mac- hine, check that it is in satisfactory working order, has been properly maintained and that any associ- ated electrical components are sealed to prevent ignition in the event of a refrigerant release.
Page 69
• • • • • • • Kατά τις λειτουργίες Ψύξης ή Θέρμανσης, πατήστε αυτό το πλήκτρο για να θέσετε σε εφαρμογή τη λειτουργία Ύπνου. Μόλις την θέσετε σε εφαρμογή, εμφανίζεται στην οθόνη του τηλεχειριστηρίου η ένδειξη “ ”. Η λειτουργία Ύπνου διαθέτει τρεις...
Page 70
Λειτουργία Ύπνου1. Η λειτουργία Ύπνου 1 “ “ είναι διαθέσιμη σε λειτουργίες Ψύξης ή Θέρμανσης. Ενεργοποιώντας τη λειτουργία, η θερμοκρασία του κλιματιστικού αυξάνεται κατά 1 βαθμό την ώρα σε λειτουργία “Ψύξης” και μειώνεται κατά ένα βαθμό ανά ώρα σε λειτουργία “Θέρμανσης”. Λειτουργία...
Page 71
κλιματιστικό θα μειωθεί κατά ένα βαθμό ανά ώρα στις πρώτες 3 ώρες από την ενεργοποίηση της λειτουργίας και στη συνέχεια θα παραμείνει σταθερή. Λειτουργία Ύπνου 3. Η λειτουργία Ύπνου 3 “ ” είναι διαθέσιμη σε λειτουργίες Ψύξης ή Θέρμανσης. Ενεργοποιώντας τη λειτουργία μπορείτε να δημιουργήσετε το δικό σας εξατομικευμένο...
Page 73
• • Αφότου ξεκινήσετε την λειτουργία TIMER ON και TIMER OFF, θέστε τη συνεψή κίνηση. Μετά από αυτό το κλιματιστικό θα ενεργοποιείται ή θα απενεργοποιείται σύμφωνα με το ρυθμισμένο χρόνο. • • • Η λειτουργία Quiet μπορεί να ρυθμιστεί σε όλες τις λειτουργίες. Όταν η λειτουργία...
Page 77
ΛΕΙΤΟΥΡΓΙΑ SELF CLEAN Όταν το κλιματιστικό βρίσκεται εκτός λειτουργίας, πατήστε ταυτόχρονα τα πλήκτρα “MODE” και “FAN” για 5 δευτερόλεπτα για να ενεργοποιήσετε ή να απενεργοποιήσετε τη λειτουργία SELF CLEAN. Μόλις ενεργοποιηθεί η λειτουργία SELF CLEAN, θα φανεί η ένδειξη “CL” στην εσωτερική μονάδα.
Page 103
ΣΗΜΕΙΩΣΗ: Όταν περνούν πολλαπλά τρύπα καλώδια θα πρέπει να λειάνετε την οπή από τα αιχμηρά γρέζια προκειμένου να μην καταστραφούν τα (N . m) καλώδια . 1/4'' 3/8'' 30~40 1/2'' 3/4'' 、12K N(1) L(3)
Page 108
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΤΗ ΣΕ ΕΣΩΤΕΡΙΚΑ ΕΞΑΡΤΗΜΑΤΑ Μην εφαρμόζετε κάποιο μόνιμο επαγωγικό ή χωρητικότητας φορτίο στο κύκλωμα, μη διασφαλίζοντας ότι αυτό δεν θα υπερβαίνει την επιτρεπόμενη τάση κατά τη λειτουργία του. Εσωτερικά εξαρτήματα ασφαλείας είναι οι μόνοι τύποι που μπορούν να χρησιμοποιηθούν, όταν βρίσκονται σε εύφλεκτο περιβάλλον.
Page 109
ΣΗΜΕΙΩΣΗ: Ο εξοπλισμός πρέπει να φέρει την ένδειξη ότι έχει αφαιρεθεί και αδειάσει το ψυκτικό. Η ετικέτα πρέπει να φέρει ημερομηνία και υπογραφή. Για συσκευές που περιέχουν εύφλεκτα ψυκτικά, βεβαιωθείτε ότι υπάρχουν ετικέτες στον εξοπλισμό που αναφέρουν ότι ο εξοπλισμός περιέχει εύφλεκτο...
Page 110
Δήλωση Συμμόρφωσης έχει χορηγηθεί στον κατασκευαστή και εί- ναι στη διάθεση των αρμοδίων αρχών εποπτείας της αγοράς. Certifi cate of compliance CE TOYOTOMI CO., LTD declares that this product complies with the general requirements pursuant to the following European Directives: LVD: 2014/35/EU...
Page 112
Quedan prohibidas la reimpresión y reproducción de este manual o partes del mismo sin permiso previo por escrito de TOYOTOMI EUROPE SALES SPAIN S.A É proibida a reimpressão ou reprodução total ou parcial deste manual, de qualquer forma, sem autorização escrita por parte da TOYOTOMI CO., LTD. ΕΠΙΣΗΜΗ ΑΝΤΙΠΡΟΣΩΠΕΙΑ ΕΛΛΑΔΑΣ Γ.Ε.ΔΗΜΗΤΡΙΟΥ Α.Ε.Ε.