Advertisement

Available languages

Available languages

4. Properly connect the live wire, neutral wire and grounding wire of power
socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
6. Do not put through the power before fi nishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualifi ed persons in order to avoid a hazard.
8. The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring
regulations.
Grounding requirement
1. The air conditioner is the fi rst class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be
used for other purposes.
3. The grounding resistance should comply with national electric safety
regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm
in all poles should be connected in fi xed wiring.
Air switch capacity
Including an air switch with suitable capacity, please note the following table.
Air switch should be included magnet buckle and heating buckle function, it
can protect the circuit-short and overload. (Caution: please do not use the fuse
only for protect the circuit).
Air-conditioner
9Κ & 12Κ
18K
24Κ
Air switch capacity
10Α
16Α
25Α
36
GB