Available languages

Stick the label on the system after fi lling is fi nished (or haven't fi nished).
Don't overfi lling.
After fi lling is fi nished, please do the leakage detection before test running;
another time of leak detection should be done when it's removed.
Safety instructions for transportation and storage
Please use the fl ammable gas detector to check before unload and open
the container.
No fi re source and smoking.
According to the local rules and laws.

Installation of outdoor unit

Step 1: Fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the
house structure.
2. Fix the support of outdoor unit on the
selected location with expansion screws.
NOTE
Take suffi cient protective measures when installing the outdoor unit.
Make sure the support can withstand at least four times of the unit weight.
The outdoor unit should be installed at least 3cm above the fl oor in order
to install drain joint.
For the unit with cooling capacity of 2300W ~ 5000W, 6 expansion screws
are needed, for the unit with cooling capacity of 6000W~8000W, 8 expansion
screws are needed, for the unit with cooling capacity of 10000W~16000W,
10 expansion screws are needed.
at least 3cm above the fl oor
46