Step 2: Install drain joint
(only for some models)
1. Connect the outdoor drain joint into the hole on
the chassis, as shown in the picture below.
2. Connect the drain hose into the drain vent.
NOTE
As for the shape of drainage joint, please refer to the current product. Do not
install the drainage joint in the severe cold area. Otherwise, it will be frosted
and then cause malfunction
Step 3: Fix outdoor unit
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
Step 4: Connect indoor and outdoor pipes
1. Remove the screw on the right handle of
outdoor unit and then remove the handle.
2. Remove the screw cap of valve and aim
the pipe joint at the bellmouth of pipe.