5. RAM CLEAR, DATA CLEAR, STATUS CLEAR
5.3

STATUS Clear

Performing the STATUS Clear operation will clear an error and the key locked condition, however, the sales data
and the programmed data will not be cleared by this operation. When the STATUS Clear is operated to clear a
key locked condition during sale, the sale item data that has already been entered for the current sale will be
cleared.
The STATUS Clear operation obtains the condition "after all sales data reset" which is required for some
programming operations, but this operation will not affect any sales data. This condition is obtained by taking
reset reports. In case you do not want to reset the sales data such as in business hours, this function is effective.
Depending on the programming item, sales data should be reset instead of STATUS Clear to keep consistency
between programmed data and sales data.
The STATUS Clear can be performed in 2 methods shown below.
< Method 1 >
1.
Unplug the ECR to turn OFF.
2.
Use the S key to turn the Mode Lock to "BLIND" position.
3.
Plug in the ECR to turn ON, causing the following message is displayed.
4.
Depress the [AT/TL] key.
5.
A STATUS Clear receipt is issued.
< Method 2 >
1.
Turn the Mode Lock to "SET" position.
2.
Depress the [9] key (Numeric key) then the [ST] key.
3.
A STATUS Clear receipt is issued.