Warming Up At The Release Of Low Power Consumption Mode - Toshiba TXZ+ Series Reference Manual

Hide thumbs Also See for TXZ+ Series:
Table of Contents

Advertisement

1.3.3.2. Warming up at the release of Low Power Consumption mode

Warming up may be required because of stability of an internal oscillator at the time of mode transition.
When shifting from STOP1 mode to a NORMAL mode, an internal oscillation is chosen automatically and the
warming up timer is started. The Output of a system clock is started after warming up time progress.
For this reason, before executing the command which shifts to the STOP1 mode, set up warming up time by
[CGWUPHCR]<WUPT[15:4]>. For the setting method, refer to "1.2.4.1. The warming up timer for a high speed
oscillation".
The following table shows the necessary of a warming up setup at the time of each Operation mode transition.
NORMAL →
NORMAL →
NORMAL →
IDLE
STOP1
STOP2
Table 1.9 Warming up
Operation mode transition
IDLE
STOP1
STOP2
NORMAL
NORMAL
RESET
NORMAL
Clock Control and Operation Mode
Warming up setting
Not required
Not required
Not required
Not required
Required (Auto Warming up)
Not required
31 / 72
TXZ+ Family
TMPM3H Group(1)
2022-05-10
Rev. 1.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmpm3hCg-m3h-dCg-m3h1-d

Table of Contents