Galanz XQG80-Q812DE After-Sales Service Manual page 23

Automatic drum washing machine
Table of Contents

Advertisement

(P06 position)
C06 电机转动方向
测试(P07 位置)
C06 motor
rotation direction
test (position P07)
C07 外筒泄漏测试
(P08 位置)
C07 outer cylinder
leakage test
(P08 position)
C08 排脱水测试
(P09 位置)
C08drain water
test
(p09 position)
C09WiFi 测试
(P10 位置) (仅
XQG80-Q812E/W
机型测试此项)
C09 WiFi test
(p10 position)
(Only model
XQG80-Q812E/W
was tested)
注:
Note:
◆测试过程中,检测故障报警,如在当前阶段发生时,立即报警,并停止执行程序。检测模式中的报错
包括:变种报错,开门报错,关门报错,NTC 报错,溢水报错,电机报错。如果发生错误,会立刻排
水,关闭其他的负载。
◆During the test, detect the fault alarm, if it occurs in the current stage, alarm immediately and stop
the execution of the program. The error reports in the factory mode include: variant error, door
opening error, door closing error, NTC error, overflow error, and motor error. If an error occurs, the
water will be drained immediately and other loads will be shut down.
◆在 D-LED MODEL 机型中,在各阶段测试时剩余时间窗口显示"C01~C08"。
◆In the D-led model, the remaining time window displays " C01~C08" in each stage of test.
◆在自动检测模式执行过程中:任何按键及旋钮均不响应,退出模式为旋钮关闭电源(P00 位置) 。
up water to the heating water level first, then start the heating, set the heating
time
正转设定时间
Forward rotation setting time
判断水位是否已在洗涤 1 水位,如未到必须先补水至洗涤 1 水位,反转设定时
Judge whether the water level is at the level of washing 1, if not, make up
water to the level of washing 1, and reverse the set time
先排水至空筒 0 水位以下,然后以最高速脱水(无须不平衡检测) ,加速及高速
过程持持续设定时间,关闭电机输出。
First drain water to the level below 0 of the empty cylinder, then dehydrate at
the highest speed (without imbalance detection), and the motor output will be
turned off when the acceleration and high-speed process lasts for a set time.
由手机或者路由器发出名字为"tuya_mdev_test"的热点,进入检测模式后旋转
到 P10 位置显示屏显示"C09",等待 10s,WiFi 模块正常则显示"on",不正常
则显示"off"。
A hot spot named "TUYA_MDEV_TEST" is issued by the mobile phone or
router. After entering the detection mode, rotate to P10 and the display
screen displays "C09". Wait for 10s. The WIFI module displays "ON" when it
is normal, and "OFF" when it is not normal.
XYJGT80QFSDE-001