XYJGT90100TVE-001 丝绸 ● ● ● ● ● Silk 羊毛 ● ● ● ● ● Wool 化纤 ● ● ● ● ● Synthetic 注:○表示没有此程序,●表示有此程序。 Note: ○ means no such program, ● means there is such a program. 2.通用规范 General Specifications 2.1 电源规格 Power Specification 220V-240V~,50Hz 2.2 平台规格...
XYJGT90100TVE-001 漂洗+脱水 ○ ○ ○ ○ Rinse+Spin 静梦洗 Night Wash 快洗 Quick 混合 ○ Mixed Fabrics 混合 ○ ○ ○ ○ Mixed 丝绸 Silk 羊毛 Wool 化纤 Synthetic 注:○表示此机型没有此程序,数字表示此程序的洗涤容量。 Note: ○ means this machine does not have this program; the number means the washing capacity of the program.
Page 7
发热管 230V~,1900W Heating element 温度传感器 电阻 R (25℃)=12kΩ Temperature Resistance R(25℃)=12kΩ sensor 选项开关 旋钮 Options Knob switch 250V~,电磁门锁 250V~,电磁门锁 门锁开关 250V~, 250V~, 250V~, 250V~, 250V~, Interlock Electromagnetic Electromagnetic switch lock lock 进水阀 220V-240V,50Hz/60Hz Water valve XQG90-T514VE/XQG90-T514VE(新欧标 New European Standard)/XQG100-T514VE XQG90-T614VE/XQG100-T614VE...
XYJGT90100TVE-001 5.功能设置及显示 Function Settings and Display 5.1 控制面板 Control Panel Figures XQG90-T514VE/XQG90-T614VE XQG90-T514VE(新欧标 New European Standard) XQG100-T514VE/XQG100-T614VE...
XYJGT90100TVE-001 5.2 面板操作 Panel Operation 5.2.1 整机状态描述 Complete machine status description 当前状态 描述 Current state Describe 掉电 电源线没有插接,没有电源输入 Outage The power cord is not plugged in, there is no power input 只插上电源,无需任何按键操作,所有显示器和负载均关闭 关机 Just plug in the power, without any key operation, and all the displays and loads are off 待机...
Page 17
XYJGT90100TVE-001 所选程序立即启动 启动/暂停 The selected program starts Start/Pause immediately 温度 选择洗涤温度 Temp Select the wash temperature 转速 选择脱水转速 待机 Speed Select the spin speed Standby 加漂洗 选择漂洗次数 Rinse+ Select the rinse times 预约 选择程序预约时间 Delay Select the program appointment time 旋钮...
XYJGT90100TVE-001 预约 无反应 Delay No response 旋钮(除“OFF”档) 改变运行程序 Knob Change the running program (Except “OFF”) 启动/暂停 预约启动或暂停 Start/Pause Delay start or pause 预约暂停可选择洗涤温度 温度 The washing temperature can be Temp selected when the appointment is suspended 预约暂停可选择脱水转速 预约 转速 The dehydration speed can be Delay Speed selected when the appointment is...
XYJGT90100TVE-001 runs at a lower speed during dehydration. 5.3.3 温度 Temp 在程序启动前按下“温度”按键,可选择不同的程序洗涤温度,部分程序温度不可选。 Press this button repeatedly to change the wash temperature. But some program temperatures are not optional. 5.3.4 转速 Speed 按压此按键可以选择不同的脱水转速。 Press this button repeatedly to change the spin speed. 5.3.5 加漂洗...
"OFF". 6.服务测试程序 Service Testing Procedures 6.1 按键注释 Key Notes: 以 XQG90-T514VE 为注释模型,各机型的检测模式按键注释位置是一样的。 Take XQG90-T514VE as the note model,the position of key notes for detection mode are the same for each mode. K1 键:Delay;K2 键:Rinse+;K3 键:Speed;K4 键:Temp;K5 键:Start/Pause; K1:Delay;K2:Rinse+;K3:Speed;K4:Temp;K5:Start/Pause; 6.2 检测模式 Detection Mode 将旋钮旋至...
Page 21
XYJGT90100TVE-001 execute the automatic detection mode; if you turn the program knob, the program will execute the manual detection mode. The specific process is as follows: 设定 Set up 描述 Describe C01 预洗阀测试 (P02 位置) 注水设定时间 C01 pre washing valve Water injection setting time test (P02 position)
XYJGT90100TVE-001 and stop executing the program. ◆在各阶段测试时剩余时间窗口显示“C01~C08”。 ◆The remaining time window displays " C01~C08" in each phase of the test. ◆在自动检测模式执行过程中:任何按键及旋钮均不响应,拔电源退出模式。 ◆In the process of automatic detection mode: any key and knob do not respond, pull the power to exit the mode. ◆在检测模式中:...
Page 23
XYJGT90100TVE-001 the set water tap is not Start level is not open stop reached within 2、排水管未 the set time; reset 挂起 2、挂起排水管 2. The drain 2.Hook up the hose is put hose down 3、检查水位开关 3、水位开关 和空气管装配, 或 或空气管漏 更换 气 3.
Page 24
XYJGT90100TVE-001 启动 暂停 键复 1、门未关好 1、检查门是否关 好 位 1. The door is not locked 1. Lock the door Start well well stop reset 2、门锁故障 2、更换门锁 2. Door lock 2. Change the 1、在尝试锁门或 is damaged door lock 解锁时,门不能锁 上或解锁 3、接线端子 1.When trying to 未插好或线...
Page 25
XYJGT90100TVE-001 setting time of 2、排水管堵 塞 drainage 2、疏通排水管脏 reset 堵 2. The drainage 2. Check the system drainage system pipes are and clean it blocked 3、排水泵故 障 3、更换排水泵 3. The drain 3. Change the pump is drain pump damaged 4、排水泵线 束插头松动、...
Page 26
XYJGT90100TVE-001 1、闭合门 锁,关闭所 有负载,排 水至空筒水 位后再持续 1、进水阀故 排设定时 障 1、更换进水阀 间; 1.The water 1. Change the 1.Close the valve is water valve door lock, damaged close all loads, drain to the empty cylinder water level 2、水位开关 筒内水位超高(水 for setting 或线束故障 位开关检测到溢...
Page 27
XYJGT90100TVE-001 1、电机线束 端子松动或 1、电机无转速反 1、检查线束端子 线束故障 馈 插接是否牢固或 1. The 1.No speed 更换线束 connection feedback of 1. Check the between the motor connection and motor and ensure it is wire is not 2、电机温升过高 secure or change secure or 2.The wire wire is temperature rise damaged...
Page 28
XYJGT90100TVE-001 5、检查线束端子 5、UVW 短 插接是否短路或 路; 电机线圈 更换电机 绝缘损坏 5. Check the 5. UVW connection and short circuit; ensure wire is motor coil not short circuit insulation or change the damage motor 6、检查线束端子 插接是否牢固或 6、UVW 接 更换线束 线脱落 6.Check the 6.
Page 29
XYJGT90100TVE-001 short circuit flag bit timeout 1、发热管线 束端子松动 1、检查线束端子 或线束故障 1、加热超时(连 插接是否牢固或 跳过加热阶 续加热设定时间, 1.The 更换线束 段,程序结 检测温度 NTC 数 connection 1. Check the 束后报警 值变化小于 2) between the connection and Skip the heating tube 1.Heating timeout ensure it is heating and wire is (continuous...
Page 30
XYJGT90100TVE-001 1、水加热温 度传感器线 束端子松动 1、检查线束端子 或线束故障 插接是否牢固或 1. The 更换线束 connection 1. Check the between the 水加热温度传感 跳过加热阶 connection and wire and 器电压值范围异 段,程序结 ensure it is temperature 常(短路或断路) 束后报警 secure or change 水加热温度 关闭 sensor is not wire Abnormal voltage Skip the 传感器故障...
XYJGT90100TVE-001 8.爆炸图 Exploded View 以 XQG90-T514VE 为模型,不同机型差异较大的组件会将爆炸图列出 Taking XQG90-T514VE as the model, the components that differ greatly between models will be listed in the exploded view.
Page 32
XYJGT90100TVE-001 零部件清单 Parts and components break-down: XQG90-T514VE: Code Name Name ntity 拉盖 XT5QG90.6.1-2(978) Drawer 门铰加强板 XT5QG90.5-6(584) Hinge Support Plate 外铁线 XT5QG90.7-10(584) Outer Gasket Clamp 进水斗 XT5QG90.6.2-1(584) Inlet Housing 内铁线 XT5QG90.7-11(584) Inner Gasket Clamp 洗衣粉盒 XT5QG90.6.1-1(584) Detergent Dispenser...
XYJGT90100TVE-001 门扣 XT5QG90.5-4(584) Door Hook 门拉手扭簧 XA4QG70E.5-9(062) Handle Spring 门拉手轴 XA4QG70E.5-10(062) Handle Pin 门扣定位架 XD7QG70V.5-5(518) Door Hook Support 门拉手 XT5QG90.5-1(978) Door Handle 门拉手轴 XT5QG90.5-8(584) Handle Pin 门铰 XT5QG90.5.1-1(584) Door Hinge 门内座 XT5QG90.5-2(584) Door Inner Frame 玻璃窗 XT5QG90.5-3(584) Door Glass 门外座 XT5QG90.5-9(978) Door Outer Frame 门装饰圈...
1. When removing sheet metal parts, please wear gloves and protect them to avoid injury. 2. When assembling all parts, please assemble them according to the original condition. 9.2 拆卸步骤 Disassembly Procedure 以 XQG90-T514VE 为拆卸模型 Take XQG90-T514VE as the disassembly model 注意事项 拆卸工序 简要说明...
Page 37
XYJGT90100TVE-001 1、 拆出的顶盖板和后 1、用十字批拆除固 定顶盖板螺钉 1、2 盖板做好防刮花保护 2、用手把顶盖板往 后推,取出顶盖板 1. The top cover as 3、用十字批拆除后 and back cover 盖板六个螺钉 3、4、 removed shall be 5、6、7、8 protected against scratching 1. Remove the screws 1 and 2 使用工具 fixing the top cover using tools plate with a cross screwdriver 2.
Page 38
XYJGT90100TVE-001 1、 在拆除图一位置时 注意避免掰断扣位 5 2.用十字批拆除左图 中螺钉 1、2、3、4 1.Pay attention to 3. 拆面板组件时先 the marked buckle 5 掰图一标示的扣位 5 position when 同时将面板组件向 removing the 外翻转约 90 度 position in fig.1 to avoid breaking the buckle 2. Use a cross screwdriver to exit the screws 1,2,3 and 4 circled in fig.2 图一...
Page 39
XYJGT90100TVE-001 1、 使用剪钳时注意不 4、用剪钳剪去图中 所示两段扎带 1、2 要剪断线组 2、 注意拔出接线端子 5、拔出电脑板上的 接线端子 3、4、5、 时请戴防静电手套 6、7、8 并整理线束 3、 装机时需另外补充 两条扎带 6、取出面板组件后 做好防静电和防刮 花保护 1. When using the diagonal cutters, be 4. Use diagonal careful not to cut the cutters to cut out thread two sections of tie 1 2.
Page 40
XYJGT90100TVE-001 take out the upper 使用工具 frame using tools 2. Pay attention to the scraping hand when taking out the upper frame 十字批 防护手套 cross gloves screwdriver 拆除门组件 Remove door 1、 拆出的门组件做好 1、打开门组件用十 字批拆除螺钉 1、2 防刮花保护 2、 拆除螺钉时注意前 2、把门组件抬起同 时取出门组件,做好 盖板不要刮花...
Page 41
XYJGT90100TVE-001 1、 拆除螺钉时注意前 1、用十字批拆除左 图的七个螺钉 1、2、 盖板不要刮花 2、 拆出的门锁和挡水 3、4、5、6、7 片注意做好防护措施 2、取出前盖板后, 取出门锁并把门锁 端子拔出,做好防护 1. Don't scratch the front panel when 1. Use the cross removing the screw screwdriver to exit 2. Pay attention to the seven screws 1, protective measures 2, 3, 4, 5 and 6 in for the door locks the left figure...
Page 42
1、拔出进水阀组件 XYJGT90100TVE-001 两个接线端子 1、2 水阀接线端子 1、 2 的 1、 注意原机器上的进 箱体背面 2、用十字批拆除背 the back of cabinet 面两个螺钉 3、 4, 取 顺序,重装时不要接 2、注意拆 3、4 位置 反 出进水阀组件 的螺钉时不要刮花箱 体 1. Pull out the two terminals 1 and 2 of 1. Pay attention to the water valve the sequence of 2.
Page 43
1、用平口钳把排气 XYJGT90100TVE-001 软管管夹 1 夹紧并拔 2、从扣位 2 中取出 出 进水斗组件 3、抬起进水斗组件, 把进水软管挂钩往 上提,直到脱出扣位 为止(见左图一) 4、握住进水软管, 用力往下拉(见左图 二) 5、拆出的进水阀、 进水斗组件取出并 做好防护 使用工具 using tools 1. Clamp and pull out exhaust hose clip 1 with combination pliers 2. Take the inlet 图一 housing out of the 平口钳...
Page 44
XYJGT90100TVE-001 1、 使用剪钳时注意不 1、用剪钳剪去左图 外桶后盖 中四段扎带 1、 2、 3、 要剪断线组 rear tub 2、 拔出接线端子时注 意端子不要扯断线 2、拔出外桶后盖上 的发热管和电机线 组 5、6、7、8、9、 1. When using the diagonal cutters, be careful not to cut the 1. Use diagonal thread cutters to cut out 2. Pay attention not the four segments to break the wire of tie 1, 2, 3 and 4 in...
Page 45
XYJGT90100TVE-001 and take out the may cause alarm balancer 2. Remove the 使用工具 upper balancer to be handled gently to avoid damage 3. Pull out the water level switch terminal 4, 5 and 6, turn the water level switch 13 号外六 电批...
Page 46
XYJGT90100TVE-001 1、 提起外桶时应避免 1、整理线束和水位 传感器 碰到线组、 水位开关、 箱体、滤波器或橡胶 2、紧握外桶拉簧两 端用力往上提直到 件 外桶完全脱离箱体 2、 外桶拿出后应轻拿 为止,在提吊桶过程 轻放,避免碰烂外桶 中注意不要压线或 或电机组件 碰到其它物料 3、 堆放时请门密封圈 向下,皮带轮向上 1. Organize harness and water 1. When lifting the level sensor tub, avoid touching 2. Hold both ends of the harness, water the suspension level switch, cabinet,...
Page 47
XYJGT90100TVE-001 1、拔出排水泵上 1、 排水泵线组按下自 的零火线 1、2 锁开关后再拔出线 2、用十字批退出 组,避免变形或拉断 固定排水泵的四 2、 拆除或安装排水泵 个螺钉 3、4、5、6 螺钉时请注意不能滑 3、用平口钳夹紧 牙或漏装,避免产生 管夹 7 同时用力拔 噪音 出排水管 1. Press the 1. First pull out the self-locking switch zero live wire 1 and on the drain pump 2 on the drain pump line group and then 2.