Use safety extra-low voltages only: max. 24 V DC.
The power supply unit must be operated only with a power supply with a
grounding conductor.
Establishing and interrupting electrical connections
Maximum permissible current loads for cables and devices must not be exceeded.
Use only connecting cables with safety plugs for electrical connections.
When laying connecting cables, make sure they are not kinked or pinched.
Do not lay cables over hot surfaces.
Make sure that connecting cables are not subjected to continuous tensile loads.
Devices with a ground connection must always be grounded.
When replacing fuses, use specified fuses only with the correct current rating and
tripping characteristics.
The device is not equipped with an integrated fuse unless specified otherwise in
the technical data.
Always pull the safety plug when disconnecting connecting cables – never pull the
cable.
Safe operation of the device is no longer possible in the event of:
Protect the device against inadvertent restart.
© Festo Didactic 8129444
Electrical connections may be established only in the absence of voltage.
Electrical connections may be interrupted only in the absence of voltage.
Always compare the current ratings of the device, the cable and the fuse.
If these are not the same, use a separate upstream fuse in order to provide
appropriate overcurrent protection.
Hot surfaces are identified with a corresponding warning symbol.
If a ground connection (green and yellow laboratory socket) is available, it
must always be connected to protective ground. The protective ground must
always be connected first (before connecting voltage), and must always be
disconnected last (after disconnecting voltage).
Some devices have a high leakage current. These devices must be additionally
grounded with a grounding conductor.
Visible damage,
Malfunction,
Inappropriate storage or
Incorrect transport
Switch off the power supply immediately.