INSTALLATION

Terminating the Wiring
at the Master Panel
Refer to Figure 1.
1. Dress the speaker wire (NuTone Model: IW-6) thru the
oblong hole in the top of the master unit's rough-in frame.
2. Cut the speaker wire to allow approximately 2' of wire to
extend thru the top of the rough-in frame.
Refer to Figure 2.
3. Strip 6" of the outer insulation from each piece of speaker
wire.
Refer to Figure 3.
4. Using a piece of tape or a wire tie, bind the speaker wiring
together.
Refer to Figure 4.
5. Separate and cut the speaker wire into color groups.
Refer to Figure 5.
6. Strip 3/8" of insulation from each strand of speaker wire.
Refer to Figure 6.
7. Using a pair of pliers, twist the bare end of each colored
set together.
Refer to Figure 7.
8. When this procedure has been completed, the speaker
wire is ready for connections at the Master Unit location.
CUT HERE
FIGURE 1
FIGURE 3
3
6"
FIGURE 2
CUT HERE
ORN
ORN/WHT
RED
BLK
RED/WHT
BLK/WHT
FIGURE 4
3
"
8
FIGURE 5
FIGURE 6
FIGURE 7