NuTone IM-5006 Series Installation Instructions Manual

Radio-intercom system master station
Hide thumbs Also See for IM-5006 Series:

Advertisement

Quick Links

RADIO-INTERCOM SYSTEM
This booklet contains information for installing the
master station. All system wiring and rough-in frames
should be installed before mounting and wiring the master
station.
Refer to the installation instructions packaged with the
IM-5006 SERIES REPRESENTATIVE WIRING ILLUSTRATION
Use this diagram for reference only—see IR-510 rough-in frame
installation instructions for detailed wiring.
NUTONE CHIME
TRANSFORMER
120vAC, 60Hz
HOUSE POWER
PUSH
PUSHBUTTON FOR
BUTTON
OPTIONAL CHIME
MODULES
(UP TO 3 DOOR RUNS)
OPTIONAL
NUTONE
ELECTRONIC
DOOR CHIME
SEE CHIME
INSTALLATION
INSTRUCTIONS
200' MAX
NUTONE IW-2
IN
14 GA
GROUND
SHIELDED
AUDIO
CABLES
OPTIONAL
OPTIONAL
MUSICAL
MUSICAL
SOURCE
SOURCE
120v, 60H
(CLASS 1)
Z
(OBSERVE LOCAL CODE)
®
MODEL: IM-5006 SERIES MASTER STATION
MADE IN MASTER, 120vAC, 60H
CLASS 1 OBSERVE LOCAL CODE.
14/2 WITH
INSIDE
GROUND
ANTENNA
NUTONE S-143
(18/2) MAX 100'
ATTIC
USE 14/2 FOR RUN
BETWEEN 100-200'
(FOR RETROFIT
WITH REMOTE
TRANSFORMER
ONLY)
EARTH
GROUND
14
300' MAX
GA
S-143
RADIO/INTERCOM MASTER IN
ROUGH-IN FRAME
DOOR SPEAKER
RECESS MODEL
MOUNTS IN
HOUSING OR
SURFACE MOUNTS
18/2
300' MAX
TO ADDITIONAL
REMOTE SPEAKER
STATION
rough-in frame for detailed wiring information. For more
detailed information on wiring and mounting other system
components (i.e., speakers, remote controls, etc.), refer to
the installation instructions packaged with each separate
component.
CAUTION: DO NOT SUPPLY
POWER UNTIL LOW VOLTAGE
POWER CONNECTIONS ARE
Z
UL LISTED CLASS 2 NUTONE
MODEL 401T TRANSFORMER
MUST BE USED
TRANSFORMER
TRANSFORMER
SUPPLIED WITH
SUPPLIED WITH
MASTER
MASTER
ROUGH-IN
ROUGH-IN
FRAME
FRAME
SECONDARY
SECONDARY
24v, 40vA
24v, 40vA
MAXIMUM OF 750' RUN.
MAXIMUM OF 4000'
TOTAL WIRE.
OUTPUT MAXIMUM
19vDC, 980
PATIO SPEAKER
W/CONTROLS.
INSTALLS IN
FRAME.
DOOR SPEAKER MODELS WITH
CHIME PUSHBUTTON ALSO
REQUIRE 18/2 (S-143) TO CHIME
LOCATION OR TO MASTER IF
OPTIONAL CHIME MODULE IS USED
INSTRUCTIONS
8' 6 COND. CABLE
AND CONNECTOR
IW-6
WALL
RECEPTACLE
,
HOME
CONTROL
INTERFACE
INSIDE REMOTE
CONTROL.
IW-6
INSTALLS IN
FRAME.
rating 19vDC, 40
OUTSIDE
REMOTE
IW-6
CONTROL.
INSTALLS IN
FRAME.
rating 19vDC, 40
OUTSIDE
REMOTE
CONTROL.
INSTALLS IN
IW-6
FRAME.
rating 19vDC, 40
A
M
IW-6
IW-6
IW-6
MAX 3 CABLES
TO ONE SPEAKER
IW-6
INSTALLATION
INSIDE 5" SP.
W/CONTROL.
rating
19vDC, 40
A
M
ANGLED
DESKTOP
FRAME
INSIDE 8" SP.
W/O
IW-2
CONTROLS.
25'
INSTALLS IN
MAX
A
FRAME.
M
OUTSIDE 8"
SP. W/O
IW-2
CONTROLS.
25'
INSTALLS IN
MAX
FRAME.
A
M
OUTSIDE 8"
SP. W/O
IW-2
CONTROLS.
25'
INSTALLS IN
MAX
FRAME.
A
M
INSIDE 5" SP.
W/CONTROL.
rating
19vDC, 40
A
M
ANGLED
SURFACE
MOUNT
FRAME
INSIDE 5" SP.
W/CONTROL.
INSTALLS IN
FRAME.
rating 19vDC, 40
A
M
INSIDE 8" SP.
W/CONTROL.
INSTALLS IN
FRAME.
rating 19vDC, 40
A
M

Advertisement

Table of Contents
loading

Summary of Contents for NuTone IM-5006 Series

  • Page 1 ® INSTALLATION INSTRUCTIONS RADIO-INTERCOM SYSTEM MODEL: IM-5006 SERIES MASTER STATION This booklet contains information for installing the rough-in frame for detailed wiring information. For more master station. All system wiring and rough-in frames detailed information on wiring and mounting other system should be installed before mounting and wiring the master components (i.e., speakers, remote controls, etc.), refer to...
  • Page 2: Wiring Installation Guidelines

    12 inches from any A.C. power wiring. The Intercom System is designed to be used only with NuTone specified wire. No other wire should be used. The use of wire other than NuTone wire may result in faulty installation and improper operation. •...
  • Page 3: Installation

    Master Panel Refer to Figure 1. 1. Dress the speaker wire (NuTone Model: IW-6) thru the oblong hole in the top of the master unit’s rough-in frame. 2. Cut the speaker wire to allow approximately 2' of wire to 6"...
  • Page 4 INSTALLATION ( Continued ) Attaching the Master Panel to the Rough-in Refer to Figure 8. MOUNTING 1. Use two No. 6 x 3/8" screws to attach mounting brackets BRACKETS to the top and bottom of rough-in frame. Make sure brackets are flush to wall or rough-in. Refer to Figures 9 &...
  • Page 5: Exploded View

    INSTALLATION ( Continued ) EXPLODED VIEW REMOTE SPEAKER WIRE ELECTRO- MECHANICAL CHIME CONNECTION ELECTRONIC CHIME MODULE GROUND SCREW DOOR SPEAKER LOW VOLTAGE CONNECTIONS AC SUPPLY LEADS CONTROL P.C. BOARD BACK-UP LINE OUT BATTERY CD/TAPE MAIN P.C. BOARD PHONO SCA OUTPUT CONNECTION ANTENNA HOOK-UP SCA OUTPUT IS USED FOR AUDIO.
  • Page 6: Connecting The Antenna

    INSTALLATION ( Continued ) Connecting the Door Speakers 1. The door speaker connects to the Control P.C. board of the master station with 2-conductor, 22 gauge twisted pair wire (IW-2). 2. As illustrated, connect two wires from the door speaker to the two (2) terminals marked DOOR SPEAKER on the P.C.
  • Page 7: Back-Up Battery Connection

    WHITE TO CHIME GROUND Refer to Figure 18. 1. Connect NuTone IW-2 cable from the chime to the red and white wires, labeled Electro-Mech Chime Input. 2. Refer to the Installation Instructions packaged with the chime for complete wiring information.
  • Page 8 INSTALLATION ( Continued ) Securing the Master Panel 1. Check all wiring connections to make sure they are complete and correct. 2. Check to make sure antenna connection is secure. 3. Position the Master Panel over rough-in frame and align screw holes in Master Panel with rough-in frame.
  • Page 9: Operational Checkout

    OPERATIONAL CHECKOUT NOTE: Please refer to page 10 for a convenient Operational Checklist. 1. When the system is first powered up, the display will 8. Press the END CALL key and the ALL CALL LED will appear as 12:00 AM. To ensure that no incorrect data has go out at the initiating station.
  • Page 10 OPERATIONAL CHECKOUT ( Continued ) Operational Check List At the time of installation, NuTone recommends that the following check list is used to verify that the system is operating properly. Station Number Location Notes:...
  • Page 11 OPERATIONAL CHECKOUT ( Continued ) Setting the Radio Audio Level In most installations, the audio trimpot will not need to be adjusted. However, follow these steps if an adjustment is necessary. 1. Set the radio volume control to the maximum level at the remote speaker located closest to the master station.
  • Page 12 Reset Only” will be covering the access hole. 8. If the system is not operating properly, Using a pencil, punch a hole in the label and disconnect the AC power and notify a NuTone activate button. The master station will reset, and service representative.
  • Page 13 THESE NUMBERS ON THE IF THE REMOTE UNIT IS TO SELECTOR SWITCH MUST BE equivalent – not supplied by NuTone). Caulk across the top BE THE STATION NUMBER: and both sides of the unit only; the bottom of the unit should IN THE ON POSITION not be caulked.
  • Page 14 INSTALLER'S TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE POSSIBLE REMEDY Hum in remote speakers. The intercom wiring has been run Be certain the intercom wiring is as far away as practical too close to the household AC from the household AC power wiring. Do not run the power wiring.
  • Page 15 INSTALLER'S TROUBLESHOOTING GUIDE ( Continued ) TROUBLE POSSIBLE CAUSE POSSIBLE REMEDY The radio volume is too loud Improper setting of the program Decrease the radio audio level by turning the program when the remote speakers are audio trim pot. audio trimpot (counter clockwise) until the desired audio set on the first volume step.
  • Page 16 WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this two year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.

Table of Contents