Diagnostics; User Interface; Diagnostic Messages; Active Unit Side - Datalogic SG4-RB2-050-OO-W Instruction Manual

Sg body reflector muting safety light curtains
Table of Contents

Advertisement

SG BODY REFLECTOR MUTING

8 DIAGNOSTICS

8.1 USER INTERFACE

A user interface aids the customer to control and check the state of the light curtain, for alignment mode,
normal operation and for troubleshooting activity. User interface is composed by four LEDs and an one-digit
display on the active unit.

8.2 DIAGNOSTIC MESSAGES

8.2.1 Active unit side

The table completely explains all the visualization information except those relative to the alignment function
(see par. 7.1 – "Light curtain alignment procedure").
VISUALIZATION
NORMAL
OPERATION
SAFE
Figure 57
STATUS
DESCRIPTION
INTERLOCK
FREE BEAMS, OSSDS OFF
INTERRUPTED BEAMS,
INTERLOCK
OSSDS OFF
NORMAL OPERATION
OSSDS ON
SAFE
OSSDS OFF
NORMAL OPERATION,
EDM FUNCTION ACTIVE
SAFE, INTERLOCK
NORMAL OPERATION,
EDM FUNCTION NOT
SAFE, INTERLOCK
ACTIVE
SAFE,
OVERRIDE FUNCTION
INTERLOCK
READY TO BE ACTIVATED
FAILURE LOCKOUT
FAILURE ON ONE OR
(RECOVERABLE)
BOTH OSSDS, OSSDS OFF
LAST
FIRST
59
ACTION
USER CAN TAKE DEVICE IN
NORMAL OPERATION ACTIVATING
RESTART LINE.
USER MUST FREE BEAMS PATH
BEFORE ACTIVATING RESTART
LINE.
USER CAN ACTIVATE OVERRIDE
FUNCTION ACTIVATING THE
CORRECT SEQUENCE ON
OVERRIDE LINES.
USER MUST ACTIVATE RESET
LINE. IF ESPE DOES NOT RESET
USER MUST CONTACT DATALOGIC
TECHNICAL SUPPORT.