4 MECHANICAL MOUNTING

The active and passive units must be installed with the relevant sensitive surfaces facing each other and the
distance must be included within the operating range of the model used (see section 13).
The two units must be positioned the most aligned and parallel possible.
The next step is the fine alignment, as shown in section 7 – "ALIGNMENT PROCEDURE".
SG BODY series light curtains are provided without mounting brackets. It is possible to order
separately the accessory kits of brackets described in the following paragraphs depending on
the fastening mode required by the particular application. Please refer to section 14 –
"ACCESSORIES".

4.1 SIDE FIXING BRACKETS

As all the Datalogic SG series safety light curtains, the most common way to fix the product is by taking
advantage from the two grooves along the sides of the aluminum case, the 90° bracket system is made by
ST-5090 + IM-5018 and screws (see Figure 22).
The ST-5090 is a 4 mm thickness sheet metal. The IM-5018 is a double nut M5 tapped obtained by machine
tooling (for further details and recommended mounting positions see also paragraph 14.1).