Guidance and manufacturer's declaration

Electromagnetic emmissions
The BC 50 is intended for use in the electromagnetic environment specified below. The customer or the user of the BC 50 should assure that it is
used in such an environment.
Emissions
RF emissions CISPR 11
RF emissions CISPR 11
Harmonic emissions IEC 61000-3-2
Voltage fluctuations/flicker
emissions IEC 61000-3-3
Electromagnetic immunity
The BC 50 is intended for use in the electromagnetic environment specified below. The customer or the user of the BC 50 should assure that it is
used in such an environment.
Immunity test
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and voltage
variations on power supply
input lines IEC 61000-4-11
Power frequency (50/60 Hz)
magnetic field IEC 61000-4-8
Compliance
Electromagnetic environment - guidance
Group 1
The BC 50 uses RF energy only for its internal function. Therefore, its RF emissions are
very low and are not likely to cause any interference in nearby electronic equipment.
Class B
The BC 50 is suitable for use in all establishments, including domestic establishments
and those directly connected to the public low-voltage power supply network that
Not applicable
supplies buildings used for domestic purposes.
Not applicable
EN 60601 test level
+/- 6 kV contact
+/- 8 kV air
+/- 2 kV for power supply lines
+/- 1 kV line(s) to line(s)
+/- 2 kV line(s) to earth
<5 % UT (>95 % dip in UT) for 0.5 cycle
40 % UT (60 % dip in UT) for 5 cycles
70 % UT (30 % dip in UT) for 25 cycles
<5 % UT (>95 % dip in UT) for 5s
3 A/m
Compliance level
Electromagnetic environment - guidance
+/- 6 kV contact
Floors should be wood, concrete or ceramic tile.
+/- 8 kV air
If foors are covered with synthetic material, the
relative humidity should be at least 30 %.
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
3 A/m
If image distortion occurs, it may be necessary
to position the Model BC 50 image intensi er
further from sources of power frequency
magnetic shielding.
The power frequency magnetic fieeld should be
measured in the intended installation location to
assure that it is sufficiently low.