  • Page 1 D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong 518103, China MedPath GmbH Mies-van-der-Rohe-Strasse 8 80807 Munich, Germany 500 BT Distributor Microlife AG Bluetooth Pulse Oximeter ® Espenstrasse 139 9443 Widnau / Switzerland www.microlife.com 0482 IB OXY 500 BT EN 0122 Revision Date: 2022-01-03...
  • Page 2 Microlife OXY 500 BT Guarantee Card Microlife OXY 500 BT Name of Purchaser Serial Number Date of Purchase V2.01.E V2.01.E Alm setup Sounds Setup * SpO2 Alm Hi Beep SpO2 Alm Lo Demo PR Alm Hi Specialist Dealer Restore PR Alm Lo...
  • Page 3 Pulse Oximeter Dear Customer, Table of Contents 1 ON/OFF button This Microlife fingertip pulse oximeter is a portable non- 2 Oxygen saturation (value as percentage) 1. Explanation of Symbols invasive device intended for spot-checking of the oxygen 2. Important Safety Instructions...
  • Page 4: Explanation Of Symbols

    1. Explanation of Symbols 2. Important Safety Instructions % SpO Oxygen saturation (value as percentage)  Follow instructions for use. This document provides Batteries and electronic devices must be important product operation and safety information disposed of in accordance with the locally appli- Pulse rate (value in beats per minute) regarding this device.
  • Page 5: General Description

    A in arterial blood that is loaded with oxygen. This is a very greater than 30 % for a proper reading. measured signal obtained by a photosensitive element, will important parameter for the respiratory circulation system. OXY 500 BT...
  • Page 6: Inserting The Batteries

     6. Inserting the batteries and the measured values of the blood oxygen saturation The device must be able to measure the pulse and pulse rate go beyond the upper limit or lower limit, the properly to obtain an accurate SpO measure- After you have unpacked your device, first insert the device gives off an alert sound.
  • Page 7: Display Mode

    When the device is switched on, shortly press the ON/OFF turn on and will be ready to connect with the «Microlife 1. No batteries or 1. Replace the button 1 to switch to another display mode to select your Connected Health+»...
  • Page 8: Technical Specifications

    Pulse rate: 1 bpm of purchase. During this guarantee period, at our discre- Measurement Oxygen saturation: tion, Microlife will repair or replace the defective product precision: ±2 % (70 - 100 %) free of charge. No requirement: (≤ 69 %) Opening or altering the device invalidates the guarantee.
  • Page 9 15 - 80 % relative maximum humidity marks owned by Bluetooth SIG, Inc. and any use of such marks by Microlife Corp. is under license. Other trade- Storage conditions: -10 - +50 °C / 14 - 122 °F 10-93 % relative maximum humidity...