01/13 Rev. 5.08-01
Error sources
Notes about fault location
Status reports should be printed to check the mechanical and electronic function ca-
pabilities – provided that no obvious no defects are evident.
Data transmission
Problem
No or damaged data
[Tab. 1] Faults possibly caused by bad data transmission.
Operation panel
Problem
Display blank, but back-
ground light on or
Random frozen display
or
Random strange
characters displayed
Display dark
Button function faulty
[Tab. 2] Possible faults at the display.
SERVICE MANUAL
Possible cause
Faulty connection
Wrong interface selected
Parameter setting incorrect
Faulty cable assignment
Incorrect handshake
Selection
Plug on board loose
Board defect
Admissible cable length
exceeded
Possible cause
Operation panel does not
match the CPU board.
Operation panel was replaced
by a new one and connected
to a CPU board with change
index below -05 (e. g. A1159-
04)
Plug connector loose
Operation panel defect
CPU board defect
Plug connector loose
Buttons defect
CPU board defect
64-xx
Solution
Check interface cable
INTERF. PARAM. > EASYPLUGINTERPR>
Check, if
Interface
is set correctly
Check parameters (Baud rate, parity, stop bits,
number of data bits, data synch. - only for serial in-
terface)
Change or replace cable pin assignment, see to-
pic section
Service Electronics
Set parameter (only for serial interface)
Select standard character set
Check and if necessary plug in again
Check and if necessary replace board
Do not exceed cable length
Solution
Replace CPU board. Required change index: at
least -05, see
Spare Parts Catalog
Check and if necessary plug in again
Check and if necessary replace display
Check and if necessary replace CPU board
Check and if necessary plug in again
Check and if necessary replace operation panel
Check and if necessary replace CPU board
2
Fault location
Error sources