Download Print this page

List Of Error Messages - Novexx Solutions ALX 73 Series Service Manual

Hide thumbs Also See for ALX 73 Series:

Advertisement

07/15 Rev. 05
Loop empty
 The buffer loop of the linear dancer arm is empty. Currently, there is no label avail-
able from the loop.
The dancer arm has moved out of the control position. The warning precedes the
warning „LDU lower limit", see error
causes as the error message.
Tandem Synch.
 Communication between master and slave machine is not working.
The warning can for example show up shortly after switching the machine on, when
the communication between the machines is not yet established. If the communication
is still established within 5 minutes after the warning showed up, the warning will dis-
appear, otherwise, after the 5 minutes are over, the error message „Tandemsynch.init"
will appear, see
message.

List of error messages

1007
Command incorr.
 Unknown interface command at data interface.
1272
#!A wrong Number
 Error in command „#!A..". The value entered for the parameter is outside of the per-
mitted range (0 to 31).
1276
#!P wrong Number
 Error in command „#!P..". The value entered for the parameter is outside of the per-
mitted range (0 to 31).
1285
#-comm. incorr.
 Error in a command "#!..". The letter entered is not valid.
1401
Para value wrong
 A not defined parameter value was sent. The error occurs for example, if a product
profile was called with a wrong number (Easy-Plug command #!PC).
3000
RS232 Overrun
 RS 232 interface receive error at COM1 (Overrun).
3001
RS232 Parity
 RS232 interface receive error COM1 (Parity).
and on host computer.
SERVICE MANUAL
5147 
on page 10. The warning has the same causes as the error
Check the command that was sent to the data interface as necessary.
Enter a value within the permitted range.
Enter a value within the permitted range.
Enter a valid letter.
Correct the sent parameter values.
Press the
-key to acknowledge.
Press the
-key to acknowledge.
Check setting in labeller's function menu:
ALX 73x
Reference status messages - dispenser
5069 
on page 8. The warning has the same
(INTERFACE PARA. > COM1 PORT >
5
Dispenser status
Parity)

Advertisement

loading