Code
Name
oL3
Overtorque Detection 1
oL4
Overtorque Detection 2
oL7
High Slip Braking Overload
oPr
Keypad Connection Fault
oS
Overspeed
ov
Overvoltage
YASKAWA TOEPC7106171GA FP605 Drive Installation & Primary Operation
Causes
The acceleration/deceleration times or cycle times are
too short.
The V/f pattern does not fit the motor qualities.
The drive capacity is too small.
Overload occurred while running at low speed.
The torque compensation gain is too large.
The speed search-related parameters are set
incorrectly.
Phase loss in the input power supply is causing the
output current to change.
Overload occurred during overexcitation deceleration. • Decrease the value set in n3-13 [OverexcitationBraking (OEB)
A fault occurred on the machine.
Example: The machine is locked.
A fault occurred on the machine.
Example: The machine is locked.
The load inertia is too large.
An external force on the load side rotated the motor.
Something is preventing deceleration on the load
side.
The value set in n3-04 [HSB Overload Time] is too
small.
The keypad is not securely connected to the
connector on the drive.
The connection cable between the drive and the
keypad is disconnected.
There is overshoot.
Deceleration time is too short and regenerative energy
is flowing from the motor into the drive.
The acceleration time is too short.
The drive output cable or motor is shorted to ground
(the current short to ground is charging the main
circuit capacitor of the drive through the power
supply).
20 Troubleshooting
Possible Solutions
• Examine the acceleration/deceleration times and the motor start/
stop frequencies (cycle times).
• Increase the values set in C1-01 to C1-04 [Acceleration/
Deceleration Times].
• Examine the ratios between the V/f pattern frequency and
voltage. Decrease the voltage if it is too high compared to the
frequency.
• Adjust E1-04 to E1-10 [V/f Pattern Parameters]. Decrease the
values set in E1-08 [Mid Point A Voltage] and E1-10 [Minimum
Output Voltage]. For motor 2, adjust E3-04 to E3-10.
Note:
If the values set in E1-08 and E1-10 are too low, the overload
tolerance will decrease at low speeds.
Replace the drive with a larger capacity model.
• Decrease the load when running at low speed.
• Replace the drive with a larger capacity model.
• Decrease the value set in C6-02 [Carrier Frequency Selection].
Decrease the value set in C4-01 [Torque Compensation Gain] to
make sure that the motor does not stall.
• Examine the settings for all speed search-related parameters.
• Adjust b3-03 [Speed Search Deceleration Time].
• Set b3-24 = 1 [Speed Search Method Selection = Speed
Estimation] after Auto-Tuning.
• Correct errors with the wiring for main circuit drive input power.
• Make sure that there is no phase loss, and repair problems.
Gain].
• Decrease the value set in n3-21 [HSB Current Suppression
Level].
Examine the machine and remove the cause of the fault.
Examine the machine and remove the cause of the fault.
Decrease deceleration times in C1-02 and C1-04 [Deceleration
Times] for applications that do not use High Slip Braking.
• Increase the value set in n3-04.
• Connect a thermal overload relay to the motor, and set n3-04 =
1200 s (maximum value).
Examine the connection between the keypad and the drive.
• Remove the keypad and connect it again.
• If the cable is damaged, replace it.
Decrease C5-01 [ASR Proportional Gain 1] and increase C5-02
[ASR Integral Time 1].
• Set L3-04 = 1 [Stall Prevention during Decel = General
Purpose].
• Increase the values set in C1-02 or C1-04 [Deceleration Times].
• Perform Deceleration Rate Auto-Tuning.
• Make sure that sudden drive acceleration does not cause the
fault.
• Increase the values set in C1-01 or C1-03 [Acceleration Times].
• Increase the value set in C2-02 [S-Curve Time @ End of Accel].
• Set L3-11 = 1 [Overvoltage Suppression Select = Enabled].
1.
Examine the motor main circuit cable, terminals, and motor
terminal box, and then remove ground faults.
2.
Re-energize the drive.