golmar G2+ 4 User Manual page 29

Monitor hands-free 2-wire installation
Hide thumbs Also See for G2+ 4:
Table of Contents

Advertisement

ART /G2+ MONITOR
4
Continued from previous page.
SPECIAL CODES
Video sources available on a monitor (configure only on the master monitor).
Door panel 1
( )
Door panel 2
*
( )
Door panel 3
*
( )
Door panel 4
*
C m ra 1
a e
( )
C m ra 2
a e
*
( )
C m ra 3
a e
*
( )
*
C m ra 4
a e
Important: Only available with EL632-G2 + SE video module with 'V03' or later.
( )
( )
*
*
General door panels installations, available with EL632-G2+ SE with 'V04' or later.
To define whether the monitor is master or slave Note: ART4/G2+ monitor with V.05 or later
Master
0550
Automatic door opening upon reception of a call on a monitor (configure only on the master monitor).
Do not show the image on the monitor when receiving a call from the door panel when the monitor is in 'Do not
disturb' mode.
Activate/ deactivate the
Enable/ disable the icon
Restore the door panel(s) SoulAccess with the master code to factory default: "1234".
(1)
All door panels
8000
LED lights for night viewing (Door panel 1) during a call or communication process. (Configure only on the master
monitor).
Automatic
0450
Activation times of the outputs (Door panel 1). (Configure only on the master monitor).
Relay 1
Rel
ay 2
Configuration of the remote activation button
Delay
Configuration of the remote activation button
Delay
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the master
( )
*
monitor).
Automatic
1450
(1)
Note: Only ART 4/G2+ monitor "V.0
Visible
0111
0121
0131
0151
0141
0181
0171
0191
S
lave
1
0551
Activated
0441
Do not show
0481
images recording
in all monitors (building).
Activate
0531
of the main menu in all monitors (building).
Enable
0541
Door panel 1
8001
Always ON
0451
From
0200 (0,5s)
to
0219 (10s)0205 (3s)
From
0300 (0,5s)
to
0319 (10s)0305 (3s)
From
0400 (0,5s)
to
0419 (10s)0403 (2s)
From 5
0 00 (0,5s)
to 5
0 19 (10s)0 03 (2s)
2
Always ON
1451
7"
or later.
Not isible
v
0110
0120
0130
0150
0140
0180
0170
0190
(
S
lave
2
0552
Deactivated
0440
Show
0480
Deactivate
0530
Disable
0540
Door panel
2
Door panel
8002
8003
Always
OFF
0452
Relay1
(Door panel 1). (Configure only on the master monitor).
Relay2
(Door panel 1). (Configure only on the master monitor).
5
Always
OFF
1452
Factory setting
0111
0120
0130
0150
0140
0180
0170
0190
):
S
lave
3
Factory default
0553
0550 (master)
Factory setting
0440
Factory setting
0480 (show image)
Factory setting
0531 (
activated
)
Factory setting
0541 (
enable
)
3
Door panel 4
8004
Factory setting
0450 (automatic).
Factory setting
Factory setting
Factory setting
Factory setting
1450 (automatic).
29
Continued overleaf

Advertisement

Table of Contents
loading

Table of Contents