Monitor hands-free 2-wire installation
Hide thumbs Also See for G2+ 4:

Advertisement

Quick Links

TECHNOLOGY
28
- 0 - 20
4
22
09:27
Art 4/G2+ monitor
Hands-free
2-wire installation
N REV.0222
TART G2+ E
4

Advertisement

Table of Contents
loading

Summary of Contents for golmar G2+ 4

  • Page 1 TECHNOLOGY - 0 - 20 09:27 Art 4/G2+ monitor Hands-free 2-wire installation N REV.0222 TART G2+ E...
  • Page 2: Table Of Contents

    - Do not place in humid, dusty or smoky locations, or near sources of heat. - Before connecting the device to the mains, check the connections between the door panel, power supply unit, distributors and monitors, se the Golmar RAP-GTWIN/HF cable (2x1mm²).
  • Page 3: Characteristics

    ART /G2+ MONITOR CHARACTERISTICS Hands-free monitor. - 4,3" TFT colour screen ush button s for access and selection of menu function. - Monitor with simple installation non-polarised 2 wires bus). - User menu. - Installer menu. Image and communication settings menu - Output to auxiliary call repeater (maximum 50mA/12Vdc).
  • Page 4: Description

    ART /G2+ MONITOR DESCRIPTION MADE IN CHINA codes DIP 1 to 7 Monitor address DIP 8 resistor OFF = 0 ON = 1 Monitor status A. Speaker. Yellow ON: Standby without notification. B. Function buttons, access and selection of menu Red ON: “Do not disturb”...
  • Page 5: Installation

    ART /G2+ MONITOR INSTALLATION Avoid dusty or smoky environments or locations near sources of heat. For proper installation, use the template supplied with the product. 1. Position the top of the template at a height of 1.65m. 2. If you are going to use an embedding box to pass the wiring through, make sure that it is in line with the holes corresponding to the box model chosen and fix the connector.
  • Page 6: Main Menu

    ART /G2+ MONITOR MAIN MENU Main menu 28-04-2022 09:27 If the device is in standby (screen switched off), to access the main menu, press any of the buttons of the monitor. Then press the button located just below the corresponding icon. The device will return to standby mode after 0 seconds without activity. Press the button below icon to make changes to the system settings (see pp.
  • Page 7: Settings Menu

    ART /G2+ MONITOR SETTINGS MENU If the device is in standby (screen switched off), to access the main menu, press any of the buttons of the monitor. Then press the button located just below the corresponding icon to access the “access settings menu screen”;...
  • Page 8 ART /G2+ MONITOR Continued from previous page. SETTINGS MENU Selecting the melody and call volume: Press the button below icon to access the settings screen. In order to identify the origin of the calls when you are not in front of the monitor, select different melodies and the desired call volume.
  • Page 9 ART /G2+ MONITOR Continued from previous page. SETTINGS MENU Select the field to be modified by pressing the buttons below corresponding icons , then press the buttons below corresponding icons to adjust the value/format. Validate the changes made by pressing the button below icon .
  • Page 10 ART /G2+ MONITOR Continued from previous page. SETTINGS MENU Automatic deletion of images/videos, recording mode, internal memory and MicroSD card: Access the recordings menu as described on p. . Press the button below icon to access the selection screen. In some countries, the law does not permit the storage of images or videos for more than 30 days after recording.
  • Page 11 ART /G2+ MONITOR Continued from previous page. SETTINGS MENU To copy still images recorded on the monitor to the MicroSD card, go to the option with icon pressing the buttons below corresponding icons . Press the button below icon to access the menu for copying images to the card, then press the button below icon to perform this function.
  • Page 12: Door Panel Call Screen

    ART /G2+ MONITOR DOOR PANEL CALL SCREEN 28-04-2022 18:25 This screen is displayed when receiving a call or pressing the button below icon of the main menu. During a call, icon displayed on the screen is in green color (during the call process). In the top centre of the screen, the date and time are shown and, on the left , the source of the image is displayed...
  • Page 13: Communication Screen

    ART /G2+ MONITOR COMMUNICATION SCREEN 28-04-2022 18:25 This screen is displayed during a communication process. During a communication , icon displayed on the screen is in red color. In the top centre of the screen, the date and time are shown and, on the left , the source of the image is displayed.
  • Page 14: Image And Communication Settings

    ART /G2+ MONITOR IMAGE AND COMMUNICATION SETTINGS (Screen A) (Screen B) During a call process or during a communication process , press the button below icon for 3 seconds to access the image and monitor in call/ communication volume settings menu. Screen A Screen B Call process screen...
  • Page 15 ART /G2+ MONITOR Continued from previous page. IMAGE AND COMMUNICATION SETTINGS The following contrast control menu will then be displayed. Adjust to the desired level by pressing the buttons below icons . To access the colour control, press the button below icon .
  • Page 16 ART /G2+ MONITOR Continued from previous page. IMAGE AND COMMUNICATION SETTINGS (Screen A) The following call tone settings volume during a call process or communication settings volume during a communication process (Screen B) will then be displayed. Adjust to the desired level by pressing the buttons below icons .
  • Page 17 ART /G2+ MONITOR PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ 'Do not disturb' mode settings: If the device is in standby (screen switched off), to access the main menu, press any of the buttons of the monitor. Then press the button below icon to access the settings screen.
  • Page 18 ART /G2+ MONITOR Continued from previous page. PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ Press the button below icon to return to the main menu. If the 'Do not disturb' mode is enable (see pages 1 to 18) will be shown the icon in the main menu and the m onitor status LED will turn on...
  • Page 19 ART /G2+ MONITOR Continued from previous page. PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ ”Automatic door openning”: This selection is visible in the “Do Not Disturb” settings menu, with the special code '0441' (Doctor mode) already entered in the monitor for automatic door opening (see special Note:...
  • Page 20: Intercom Menu

    ART /G2+ MONITOR Continued from previous page. PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ Press the push button below the icon to return to the main menu screen. If the "automatic door opening" mode has been activated (see page 1 ) the icon will be displayed at the top left of the main menu screen and the led of the push button will blink in white color when the monitor is in...
  • Page 21 ART /G2+ MONITOR Continued from previous page. INTERCOM MENU To make an internal intercom call (to another monitor(s) in the same apartment), press the buttons below corresponding icons to select the monitor to be called, press the push button below the icon to make the call.
  • Page 22 ART /G2+ MONITOR Continued from previous page. INTERCOM MENU To make an external intercom call (to other apartments), go to the option with the icon by pressing the push buttons located below the corresponding icons, press the push button located below the icon to Remember: access the menu for selecting the apartment code you wish to communicate with.
  • Page 23 ART /G2+ MONITOR Continued from previous page. INTERCOM MENU The monitor making the call will sound a confirmation melody and will indicate the code of the apartment called and available call time, if you wish to cancel the call press the button below icon returning to the main menu.
  • Page 24: Recordings Menu

    ART /G2+ MONITOR RECORDINGS MENU If the unit is in standby mode (screen off), press any of the buttons on the monitor to access the main menu (see page 6). Then press the button located below the icon to access the recordings menu. This menu displays the list of images saved in the memory of the device.
  • Page 25 ART /G2+ MONITOR Continued from previous page. RECORDINGS MENU If a MicroSD card is inserted in the monitor, press the button below icon to access the list of videos. In the list of recorded videos, those that have not been viewed are with the icon .
  • Page 26 ART /G2+ MONITOR Continued from previous page. RECORDINGS MENU To return to the main menu, press the button below icon List of recorded videos screen Main menu 01/03 02-0 -2 22 11:17:10 0 -0 -2 22 6 4 0 11:17:10 28-04-2022 09:27 0 -0 -2 22...
  • Page 27: Settings And Operation Of The Guard Monitor

    ART /G2+ MONITOR SETTINGS AND OPERATION OF THE GUARD MONITOR Settings "guard monitor" mode: The monitor/s to be configured as a guard monitor/s (up to 4 monitors) in the building, must be configured with address 1 and as master slave 1 slave 2 slave 3 .
  • Page 28: Special Codes

    ART /G2+ MONITOR SPECIAL CODES The enabling of some functions, as well as the modification of some factory parameters, can be carried out by entering special codes. To do so, the installer menu must be accessed from the monitor. Go to the 'About' screen in the Settings menu (p.
  • Page 29 ART /G2+ MONITOR Continued from previous page. SPECIAL CODES Video sources available on a monitor (configure only on the master monitor). Visible Not isible Factory setting Door panel 1 0111 0110 0111 Door panel 2 0121 0120 0120 Door panel 3 0131 0130 0130...
  • Page 30 ART /G2+ MONITOR Continued from previous page. SPECIAL CODES Activation times of the outputs (Door panel ). (Configure only on the master monitor). Factory setting Relay 1 From 1200 (0,5s) 1219 (10s)1205 (3s) ay 2 From 1300 (0,5s) 1319 (10s)1305 (3s) Configuration of the remote activation button Relay1 (Door panel ).
  • Page 31: Cleaning The Monitor

    ART /G2+ MONITOR Continued from previous page. SPECIAL CODES (GENERAL DOOR PANELS) General door panels video sources available on a monitor (configure only on the master monitor). Visible Not isible Factory setting General door panel 1 1111 1110 1111 General door panel 2 1121 1120 1120...
  • Page 32: Compliance

    C/ Silici, 13 08940- Cornellá de Llobregat SPAIN Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.