Display Interfaces; Displayport (Dp) - Eaton XP-504-10-A10-A01-2B Manual

Table of Contents

Advertisement

4. Using peripheral devices - External connections

4.5 Display interfaces

4.5 Display interfaces

4.5.1 DisplayPort (DP)

78
There are two ports available for connecting additional HMI devices (terminals, mon-
itors, touchscreens) to the Human-machine interface.
Available on: Panel-PC, Box-PC, Terminal, and Extender TX with varying pinouts
19 17 15 13 11 9
7
5
3
1
20
18 16 14 12 10 8
6
4
2
Fig. 36: Pin assignment DP
Available on: Panel-PC and Box-PC
PIN
PIN
1
LANE 0_P
8
2
GND
9
3
LANE 0_N
10
4
LANE 1_P
11
5
GND
12
6
LANE 1_N
13
7
LANE 2_P
14
Available on: Terminal
PIN
PIN
1
LANE 3-
8
2
GND
9
3
LANE 3+
10
4
LANE 2-
11
5
GND
12
6
LANE 2+
13
7
LANE 1-
14
Available on: Extender TX
PIN
PIN
1
n.c.
8
2
GND
9
3
n.c.
10
4
n.c.
11
5
12
GND
6
n.c.
13
7
14
LANE 1-
XP-504 04/2022 MN048028EN Eaton.com
PIN
GND
15
AUX_DP
LANE 2_N
16
GND
LANE 3_P
17
AUX_DN
GND
18
Hot Plug Detect
LANE 3_N
19
GND
GND
20
+3.3V
GND
PIN
GND
15
AUX CH+
LANE 1+
16
GND
LANE 0-
17
AUX CH-
GND
18
Hot Plug Detect
LANE 0+
19
Return
GND
20
DP Power
GND
PIN
GND
15
AUX CH+
LANE 1+
16
GND
LANE 0-
17
AUX CH-
GND
18
Hot Plug Detect
19
LANE 0+
Return
GND
20
n.c.
GND