2. Functional Specifications
2.1
Configuration of the Power Supply
The power to the M32R/ECU can be supplied from two sources, AVCC and VCCE independently of
each other. With default settings, the power to the M32R/ECU is fed through the VCCE power
supply connector to all of its internal circuits.
Note: H1, TX1 and TX18 are not mounted but they only have patterns available.
Figure 2.1 Power Supply Circuit
Table 2.1 Configuration of the Power Supply
Power
Connector
Supply
CN1
AVCC
CN2
VCCE
—
VREF0
Note: The H1 and H6 jumpers are shorted by soldering.
REJ10B0224-0310/Rev.3.10
Jumper
Name
Default
H1
—
—
H6
Starter Kit User's Manual M3A-2152
Condition
Shorted
Power supply from VCCE (CN2)
between 1–2
Shorted
Power supply from AVCC (CN1)
between 2–3
—
VCCE power supply
Shorted
Power supply from AVCC
between 1–2
Mar. 2008
32176 Group
Description