6. Error Message List

Table 6.1.1 lists error messages, causes, and approaches provided from the M3S-UFLA32R.
Table 6.1.1 Error Message List
Error Message
1
MCU information is incorrect.
Please check whether the "UFLA32R.ini"
file is installed correctly.
2
Can not open COM1.
3
Motorola file is not specified.
Please specify Motorola file.
4
The specified file is not a S-format file.
Please specify S-format file (*.mot).
5
Address Error.
Start Address < NNNNNNNNh
6
Address Error.
End Address > NNNNNNNNh
7
Receive timeout error.
8
Communication parameter error.
9
Command execution error.
10
Blank Check Error.
(Error Address: H'NNNNNN)
11
Verify Check Error.
Error Address : H'NNNNNN
Error Data : H'AAAA (H'BBBB)
12
Verify Check Error.
13
ID verification error.
Please set up the ID code correctly.
14
ID code is incorrect.
Please enter ID code with Hexadecimal.
15
ID code is incorrect.
Please enter ID code correctly.
REJ10B0239-0140/Rev.1.40
UART Flash Memory Programming Utility
Cause
There is no INI file.
Can not open COM1.
Motorola S format file is not
specified.
The specified file is not Motorola
S-format file or there are some
contents errors.
The data record address of
chosen file is beyond the flash
memory.
The record length of the chosen
file has an error.
Timeout occurs during reception.
Receive reply other than ACK
and NAK from the MCU.
Receive NAK from the MCU.
There is no blank after the
address H'NNNNNN.
At the time of verify, the data of
the address H'NNNNNN are
H'AAAA (MCU side) and H'BBBB
(M3S-UFLA32R side) and not
corresponding.
Check sum value is not
corresponding at the time of
verification
The ID code in the MCU and the
one set in the M3S-UFLA32R
are different
Input ID code has an error.
Input ID code has an error.
Mar. 2007
M3S-UFLA32R
Approach
Reinstall the M3S-UFLA32R.
Check if the COM1 is used in the
other application.
Specify the Motorola S format file.
Check the contents of the
selected file or specify different
file.
Check the contents of Motorola S
format file or specify different file.
Check the contents of Motorola S
format file or specify different file.
Check the connection state of the
communication cable or restart
the M3S-UFLA32R, and then
reset the MCU.
Restart the M3S-UFLA32R and
reset the MCU.
Restart the M3S-UFLA32R and
reset the MCU.
-
Check if it is the same Motorola S
format file as the program in the
MCU.
Check if it is the same Motorola S
format file as the program in the
MCU.
Set the correct ID code to the
M3S-UFLA32R.
Enter ID code with Hexadecimal.
Enter ID code with alphanumeric
characters.
Page 30 of 30