Renesas M3S-UFLA32R User Manual page 34

Uart flash memory programming utility
Table of Contents

Advertisement

(2) In the "ID code setting" dialog, the ID code for verification is set.
Table 5.17.1 shows function list of operable and not operable functions according with the verify
result.
Choose [Specify ID code by hexadecimal] to set the ID code by hexadecimal.
Choose [Specify ID code by alphanumeric] to set the ID code by alphanumeric characters.
Click [OK] to enable the setting, and then close the "ID code setting" dialog.
Click [Cancel] to disable the setting, and then close the "ID code setting" dialog.
Note: In the 3218x Group and 3219x Group, 12-byte of the address H'84 to H'8F is enabled.
In the other MCU, 16-byte of the address H'84 to H'93 is enabled.
Figure 5.17.2 ID Code Setting Dialog
Table 5.17.1 Operable, Not Operable List
Function
Load
Exit
Lock Bit Information
Program
Erase
Block Erase
Lock Bit / Set
Lock Bit / Enable
Lock Bit / Disable
Blank Check
Verify Check
Batch processing / E.B.P.V.
Batch processing / E.P.
Batch processing / B.P.V.
Setting
ID Code Setting
Version information
Note: YES: Operable, NO: Not operable
REJ10B0239-0140/Rev.1.40
ID code is corresponding or
every ID code in the MCU is FFh
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Mar. 2007
UART Flash Memory Programming Utility
ID code is not corresponding
YES
YES
YES
YES
YES
M3S-UFLA32R
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Page 28 of 30