Installation - Philio PHI PST02-1B Quick Start Manual

Z-wave 3 in 1 sensor (motion, illumination, temperature)
Hide thumbs Also See for PHI PST02-1B:
Table of Contents

Advertisement

Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is
inoperable.
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different
brands.

Installation

Battery Installation
When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the
front cover please follow below steps.
Using a tool to press the 1-1 position, to release the cover.
Hold the front cover and pull back
Hold the front cover and pull up
Replace the new battery and install the cover back.
Put the front cover bottom to 1-1, and press down.
Push the front cover top to 2-1.

Hide quick links: