7.

JUMPERS AND USER ADJUSTMENTS

SD Present
HD Present
MODULE STATUS
3G-A Present
3G-B Present
J6
J5
7.1.

SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME

STATUS

The FRAME STATUS jumper J3, located at the front of the module determines whether local faults (as
shown by the Local Fault indicator) will be connected to the 7700/7800 series frame's global status bus.
FRAME STATUS:
To monitor faults on this module with the frame status indicators (on the power
supply's FRAME STATUS LED's and on the Frame's Fault Tally output) install this
jumper in the "On" position.
When this jumper is installed in the "Off" position local faults on this module will not
be monitored.
7.2.

CONFIGURING THE MODULE FOR FIRMWARE UPGRADES

UPGRADE:
The UPGRADE jumper J5 located at the front of the module near the card ejector is used
when firmware upgrades are being done to the module. For normal operation it
should be installed in the RUN position. See the Upgrading Firmware section in the
front of the binder for more information.
To upgrade the firmware in the module unit pull it out of the frame. Move Jumper
J16 into the UPGRADE position. Install the Upgrade cable provided (located in the
vinyl pouch in the front of this manual) onto header J6. Re-install the module into the
frame. Run the upgrade as described in the Upgrading Firmware section in the front
of the binder. Once the upgrade is complete, remove the module from the frame,
move J5 to the RUN position, remove the upgrade cable and re-install the module.
The module is now ready for normal operation.