Page 5-20
26) Discard the supporting fluid from the plas-
tic bowl.
Note:
The supporting fluid is not poisonous.
27) Placing a thumb in the recess of the
gyrosphere, lift the gyrosphere out of the
gyrosphere container and place it in the
plastic bowl.
28) Using a lint-free cloth and alcohol, care-
fully wash and dry the gyrosphere.
Caution:
Do not use acetone or similar solvents.
29) Thoroughly clean the contact surfaces of
the gyrosphere with the stainless steel
wool pad provided in the installation and
replacement parts kit.
30) Seal the recess of the gyrosphere with a
protective sticker. Stickers are included in
the installation and replacement parts kit
and with replacement gyrospheres.
31) Pack the gyrosphere in its shockproof box
and pack the box in the original transport
container.
056310