NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
3.2
Service Setup 2
The "Service Setup 2" menu provides access to operational data that may be of
importance when service or maintenance work is carried out. Additionally, the opera-
tor may initiate a masterboard reset.
3.2.1
Access Code
In order to prevent inadvertent or unauthorized changes of the configuration settings,
the service setup modes are protected by acces codes.
To access the Service-Setup 2, enter 610.
3.2.2
Gyrosphere Data
Function:
Note:
3.2.3
Op. Time counter
Function:
3.2.4
Data List
Function:
3.2.5
Error List
Function:
Note:
3.2.6
Masterboard Reset (reset Mk 1)
Function:
Displays the gyrosphere temperature, phase bridge voltage and
gyrosphere current.
Directly after power-up, the gyrosphere current should not exceed
550 mA. The current will gradually fall while the gyrosphere settles.
Within 45 minutes after power-up, the gyrosphere current must have
dropped below 300 mA. Failing this, the gyrosphere is defective and
must be replaced.
Displays the operation time counter.
Displays a list of operational data.
Displays a list of currently detected errors. When the cause of a given
error is eliminated, the corresponding entry is automatically cleared
from the error list.
Confirming an alarm state or muting the alarm buzzer does not clear
the corresponding entry from the error list.
Initiates a reset (warm start) of the masterboard.
056310
3-149 MK110ENG.P65
Page 3-03