NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
2.4.6
Rate Of Turn Damping Time Constant / Alarm Threshold (Settings ROT)
Settings:
Function:
Note:
Settings:
Function:
damping time constant
0 - 99 s
Sets the damping time constant for the analogue rate-of-turn output.
The larger the constant, the stronger sudden peaks of the output volt-
age are damped. Damping is turned on/off by an external selector switch.
Damping is effective for the analogue rate of turn output only. The dig-
ital display and the serial outputs always put out undamped rate of turn
data.
alarm threshold
0 – 6000°/min
Sets the threshold value for the maximum rate of turn alarm. If the
actual rate of turn exceeds the set value, the rate of turn alarm relay is
actuated. Simultaneously, an alarm message is displayed and an audi-
ble alarm given.