NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
29) Attach the free end of the ventilation valve
to its neck.
30) Carefully dry the gyrosphere container with
a lint-free cloth.
31) Connect the power cable to the centering
pin and firmly tighten the terminal screw.
32) Insert the base plug connector through the
hole in the lower section of the container.
Lift the container to the shoulder, keeping
it in a vertical position. Connect the plug
to the base contact.
33) Place the container back on the work sur-
face.
34) If replacing a gyrosphere, place the pro-
vided label with the new gyrosphere's se-
rial number on the magnetic shield of the
gyrosphere container.
056310
3-149 MK110ENG.P65