Emerson Rosemount 3410 Series Maintenance And Troubleshooting Manual page 27

Gas ultrasonic flow meters
Hide thumbs Also See for Rosemount 3410 Series:
Table of Contents

Advertisement

Maintenance and Troubleshooting manual
00809-0200-3104
Figure 2-5: Meter Monitor (Detailed) view
The following details the information displayed in this dialog box.
Flow Properties Table - the table at the top of the Meter Monitor dialog box shows basic
information about the condition of the flow in the meter.
Flow Velocity/Flow Ratios Bar Graph - provides a visual comparison between the
velocities for each chord.
Chord Speeds of Sound Bar Graph - a visual comparison between the calculated speeds of
sound for each chord.
Gain/Performance Bar Graph - provides either a visual comparison of the average of the
upstream and downstream gains for each chord or a visual comparison of the average
of the upstream and downstream performance for each chord.
Signal to Noise Bar Graph - provides a visual comparison between the signal to noise
ratio for each chord direction.
Meter Status Alarms - provides a visual indication of the meter's status.
Gas Comp - this dialog shows the gas composition that can be used by the AGA8 or
AGA10 gas calculations.
Baseline - this dialog shows the meter's flow characteristics in comparison to limits
defined for the Continuous Flow Analysis features. This dialog is only available for four
path meters that support a baseline and a valid Continuous Flow Analysis key.
Run time - displays how long the monitor screen has been collecting data.
Meter Time - the time displayed is the time from the Ultrasonic meter.
Note
If the time displayed has a yellow background, that is an indication that the meter's
time is more than 10 minutes apart from the PC's time.
Meter Data List - displays read-only data selected from the drop-down list.
Rosemount 3415, 3416 and 3417
Troubleshooting
April 2022
27