2. Select the bit length with the JogDial.
The default value is 8 bits.
7: 7 bits
8: 8 bits; select 8 when using the PS•DATA protocol.
Parity Check
505 PARITY CHECK
DATA BIT
PARITY CHECK
STOP BIT
WAIT TIME
1. Move the cursor to PARITY CHECK with the [ ] or [ ]
button.
2. Select the check mode with the JogDial.
The default is NONE.
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
Stop Bit
506 STOP BIT
DATA BIT
PARITY CHECK
STOP BIT
WAIT TIME
1. Move the cursor to STOP BIT with the [ ] or [ ] button.
2. Select the number of stop bits with the JogDial.
The default is 1.
1: 1 bit
2: 2 bits
31
8
NONE
1
OFF
DISPLAY SELECT
LCD CONTRAST
8
NONE
1
OFF
DISPLAY SELECT
LCD CONTRAST
Wait Time
507 WAIT TIME
The unit retransmits data after waiting the specified time if
there is no response from the connected device. The
default is OFF.
DATA BIT
PARITY CHECK
STOP BIT
WAIT TIME
1. Move the cursor to WAIT TIME with the [ ] or [ ] but-
ton.
2. Select the waiting time with the JogDial. The default is
OFF.
OFF : Retransmission is disabled
100 MS: 100 m seconds
200 MS: 200 m seconds
1 S
: 1 second
SYSTEM INFORMATION
SYSTEM INFORMATION
HDD HOUR METER
HDD CAPACITY
DEFAULT
In the SYSTEM INFORMATION window, HDD HOUR
METER shows how many hours the digital hard disk
recorder has been operated in Playback, Recording and
Idle. The built-in HDD needs replacement when the hour
meter reads around 30 000 H.
HDD CAPACITY indicates the total usable capacity of the
built-in hard disk.
DEFAULT enables the recorder to restore all setup data to
the default values. See page 18 for details.
8
NONE
1
OFF
DISPLAY SELECT
LCD CONTRAST
1000H
.
GB
SET