Alarm Terminal Connection

A connection example is shown below.
Digital Disk Recorder
WJ-HD100
External device
REMOTE/ALARM IN
G
8
G
7
G
6
G
5
G
4
G
IN: Stands for Alarm Signal In. Connect directly with a
sensor unit or indirectly with a unit having sensor
output capability to the recorder. The recorder
enters alarm recording mode when the alarm signal
(active when low) comes in.
RESET IN: Receives the reset signal (active when low)
from a connected device.
RECOVER OUT: Supplies the reset signal when the
RESET IN is received, the [
pressed, or the AUTO RESET time elapses.
OUT: Stands for the status output active until an alarm
is reset.
RECALL: The alarm history is displayed on the Monitor
every time the external switch is turned on.
GND: Signal ground
13
ALARM
CONTROL IN
ALARM OUT
RECOVER OUT
RESET IN
3
G
2
G
1
G
G
G
NC: Normally Closed
NO: Normally Open
Relay
NO
NC
+24V
STOP] button is

RS-232C Connection

Use an RS-232C cable (not included) as shown below to
connect the RS-232C terminal with a personal computer or
the like. The protocol selection in the COMMUNICATION
SETUP must be set to VCR.
Frame
9-pin D-sub connector
PS
Data Connection
Connect the DATA terminal on the rear panel to a system
To Alarm
Indicator
component with a modular cable (not included) in the PS
Data chain. The protocol selection in the COMMUNICA-
TION SETUP must be set to PS
dure for unit address setup (page 14, 30) and termination
(page 14).
Panasonic part # WV-CA48 series, RS-485 cables and con-
nectors are recommended for the connection.
GND
RA
RX
RB
1
2
3
4
5
6
7
8
Shield
9-pin D-sub connector
(female)
(female)
DATA. Follow the proce-
GND
TB
TX
TA
DATA
1
2
3
4
5
6
7
8
Frame
TA
TX
TB
RA
RX
RB