Advertisement

Quick Links

USER MANUAL
LDR 8 s Auto Clean GAS
WARNING
Read the instructions before using the machine.
EN (Original Instruction)
LDR 8 s AC GAS
9124665 / 2203

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDR 8 s Auto Clean GAS and is the answer not in the manual?

Questions and answers

Summary of Contents for Fri-Jado LDR 8 s Auto Clean GAS

  • Page 1 LDR 8 s AC GAS USER MANUAL LDR 8 s Auto Clean GAS WARNING Read the instructions before using the machine. EN (Original Instruction) 9124665 / 2203...
  • Page 2 These instructions must be post in a prominent location. KEEP THIS USER MANUAL IN A SAFE PLACE FOR FUTURE USE © 2022 Fri-Jado B.V., Oud Gastel, The Netherlands. We advise you to contact your supplier for the guarantee period and conditions. Further we refer to our General Terms and Conditions for Sales and Delivery that are available upon request.
  • Page 3 LDR 8 s AC GAS Empty page. 3 / 32...
  • Page 4: Table Of Contents

    LDR 8 s AC GAS CONTENTS INTRODUCTION ......................6 General ..........................6 Identification of the unit ..................... 6 Pictograms and symbols ....................6 Safety instructions ......................7 1.4.1 General ........................7 1.4.2 Moving ......................... 8 Hygiene ..........................8 Service and technical support ................... 8 Shutdown / Storage ......................
  • Page 5 LDR 8 s AC GAS Interrupt a program ......................20 Reset alarm signal ......................20 Power down ........................20 SETTINGS ........................21 General ........................... 21 Overview main parameters (Manager) ................21 Service Menu ........................21 PROGRAM ........................22 General ........................... 22 Adding programs ......................
  • Page 6: Introduction

    LDR 8 s AC GAS INTRODUCTION General This manual is intended for the user of the LDR 8 s AC GAS (Large Deli Rotisserie on Gas with cleaning feature). The features and controls are being described, along with directions for the safest and most efficient use, in order to guarantee a long life of the unit.
  • Page 7: Safety Instructions

    LDR 8 s AC GAS Safety instructions WARNING The top cover (in particular the flue tube) and the outside of the unit can be very hot. WARNING Do not put any objects on the equipment as this may cause fire. Keep all openings free from obstacles.
  • Page 8: Moving

    LDR 8 s AC GAS • Cleaning and user maintenance shall not be made by children without supervision. 1.4.2 Moving When moving the unit: • Before moving the unit, first switch off the mains voltage by pulling the plug from the wall socket and empty the fat collecting container.
  • Page 9: Description Of The Unit

    LDR 8 s AC GAS Description of the unit Technical description Heating takes place by means of gas that is burnt in a heat exchanger placed in the ceiling. A fan mixes the gas and air, which mixture is ignited by means of an automatic ignition. The modulated gas combustion takes place in the inner part of the heat exchanger and is therefore not visible.
  • Page 10: Installation And First Use

    LDR 8 s AC GAS INSTALLATION AND FIRST USE All packing materials used for this unit are suited for recycling. After unpacking, check the state of the unit. In case of damage, store the packing material, and contact the transporter within fifteen working days after receiving the goods. Unpacking the unit 1.
  • Page 11 LDR 8 s AC GAS WARNING Settings on the gas equipment are secured by the manufacturer and should under no circumstances be broken by the installer. Settings must not be changed. WARNING Do not store or use gasoline or other flammable vapors or liquids in the vicinity of the appliance.
  • Page 12 LDR 8 s AC GAS Installation: • North American units must be installed conform local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable, including: i) The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½...
  • Page 13: First Use

    LDR 8 s AC GAS First use When using the unit for the first time, clean the interior thoroughly with soap suds and heat up the unit, see section 3.3.1. After commissioning discoloration of the cooking/grilling area can occur. ➊ ➋...
  • Page 14: Operation And Use

    LDR 8 s AC GAS OPERATION AND USE Control Panel Main Functions: ON / OFF Recipes Wipe/clean touch screen (during countdown) Clean Rotisserie Home screen Language Help function Tap or swipe to select function or activate additional screen Step Back (when shown at upper left corner) 14 / 32...
  • Page 15: Switching-On The Unit

    LDR 8 s AC GAS Switching-on the unit Loading the unit When the door is open press the rotor button to activate the rotor. This allow easy loading or unloading the products. Whilst loading the unit, make sure that the rotor gets evenly loaded, so that the mass of the products is evenly spread over de rotor, causing an equal balance.
  • Page 16: Grilling Time

    LDR 8 s AC GAS • Whilst loading the unit with meat baskets, you must see to it, that the rotor gets evenly loaded, so that the mass of the products is evenly spread over de rotor, causing an equal balance. •...
  • Page 17: Taking Out The V-Shape Spit (Accessory)

    This releases the spit. Take the spit at its other end and take it out of the unit. Remove the products from the spit. Refer to the You-Tube movie: “Fri-Jado instruction for unloading chicken from a rotisserie”. 4.5.2 Taking out the meat basket (accessory) When taking out the meat basket from the LDR it is best to act as follows: Slightly lift both ends of the meat basket.
  • Page 18: Operate

    LDR 8 s AC GAS OPERATE Starting a program 1. Press 2. Select the required program. The total duration of the program is shown in minutes next to the program name. 3. Press Reset burner controller Message “Burner failed, check gas supply and reset burner” appears on screen when the burner is not in operation when needed.
  • Page 19: Pre-Heating

    LDR 8 s AC GAS Pre-heating When the pre-heat function is activated (at manager menu), the unit will start this function after selecting a program. The screen will display the actual temperature (at the top). Tap on the temperature box to see the set pre-heat temperature (approx.
  • Page 20: Adding Extra Time To The Active Program

    LDR 8 s AC GAS Adding extra time to the active program During the process extra time can be added (when activated in the manager menu), by following the next steps: 1. Press 2. Set extra time. 3. Select to save setting. The display now shows the extra time, which will be added to the last cooking step.
  • Page 21: Settings

    LDR 8 s AC GAS SETTINGS General The settings of the unit can be changed by using the control panel. There are three kinds of settings: • Information • Manager • Service Select to enter the setting menu. The Manager and Service section are password protected. Press to go one level back.
  • Page 22: Program

    LDR 8 s AC GAS PROGRAM General Enter the recipe menu Adding programs 1. Select 2. Enter the program name. 3. Enter the preheat step (or left blank). 4. Add cooking steps (swipe additional step at the bottom of the screen upwards). 5.
  • Page 23: Deleting Programs

    LDR 8 s AC GAS Deleting programs Deleting of a program cannot be undone. 1. Select recipe to delete. 2. Select 3. Select 4. Select Yes. 23 / 32...
  • Page 24: Cleaning And Maintenance

    LDR 8 s AC GAS CLEANING AND MAINTENANCE WARNING Appliance must be disconnected from the power supply during manual cleaning or maintenance and when replacing parts. Do not use aggressive or abrasive materials. These will damage the surface which will make it more difficult to remove dirt. Clean the inside, the removable parts and the accessories thoroughly with cleanser and water before putting the unit into use.
  • Page 25 Contact your supplier for the appropriate Fri-Jado Rotisserie Cleaning Cartridges. Additional are Fri-Jado In Between Clean and Fri-Jado RotiShine Descale cleaning products available. Please contact Fri-Jado for more information. ProteClean disclaimer: In some cases a quick release of the second stage of the product can cause black stains in the stainless steel.
  • Page 26: Weekly Cleaning

    LDR 8 s AC GAS Weekly Cleaning WARNING The control panel may only be cleaned using a damp cloth. The exterior: • Clean the exterior with cleaning agent or hot water combined with an appropriate cleaning agent. • Dry the exterior thoroughly by using a dry cloth. Gas hose •...
  • Page 27: Malfunctions And Service

    LDR 8 s AC GAS MALFUNCTIONS AND SERVICE Before you contact your supplier/dealer in case of a malfunction, there are some items you can check yourself: • Is the power supply working properly? Check fuses and differential switch. • Has the timer clock been properly set? Item Malfunction Possible action...
  • Page 28: Technical Specifications

    LDR 8 s AC GAS TECHNICAL SPECIFICATIONS WARNING Consult the identification plate to get the proper specifications of the unit. electrical data may vary from country to country. Models Model LDR 8 s AC Dimensions Width 52 inch Depth 38 ¼ inch Height 71 ½...
  • Page 29 LDR 8 s AC GAS Notes. 29 / 32...
  • Page 30 LDR 8 s AC GAS Notes. 30 / 32...
  • Page 31 LDR 8 s AC GAS Notes. 31 / 32...
  • Page 32 LDR 8 s AC GAS Fri-Jado B.V. Fri-Jado Inc. Blauwhekken 2 1401 Davey Road, Suite 100 4751 XD Oud Gastel Woodridge IL 60517 The Netherlands Tel: +31 (0) 76 50 85 400 Tel: +1-630-633-7950 www.frijado.com 32 / 32...

This manual is also suitable for:

Ldr 8 s auto cleanLdr 8+8 s auto clean

Table of Contents