Diagram 29 Jumper Locations
H2 (BOND)
H3 (DPS)
Diagram 30 DIP-switch Locations
Magnalock Functions
Delayed Egress Functions
Table 3 Delayed Egress DIP-switch selection and function
Delayed Egress Function Dip-Switches
Nuisance Delay
Exit Delay
Bypass Time
Post Alarm Reminder
Bypass Expiration
Alarm
Manual/Delayed
Relock
Unlocked at Startup
No Irrevocable
Alarm After Bypass
Expiration
Table 1 Jumper Settings
Jumpers
JP3 (EXT INIT)
H2 (BOND)
H3 (DPS)
JP3 (EXT INIT)
Table 2 Magnalock DIP-switch selection and function
Magnalock function DIP-switches
LED enable
(Reserved)
Reset to Factory Defaults
Position
Selection
SW 1 OFF / SW 2 OFF
0 seconds
SW 1 ON / SW 2 OFF
1 seconds
SW 1 OFF / SW 2 ON
2 seconds
SW 1 ON / SW 2 ON
3 seconds
SW 3 OFF
15 seconds
SW 3 ON
30 seconds
SW 4 OFF / SW 5 OFF
0 seconds
SW 4 ON / SW 5 OFF
15 seconds
SW 4 OFF / SW 5 ON
30 seconds
SW 4 ON / SW 5 ON
45 seconds
SW 6 OFF
Disabled
SW 6 ON
Enabled
SW 7 OFF
Disabled
SW 7 ON
Enabled
SW 8 OFF
Disabled
SW 8 ON
Enabled
SW 9 OFF
Disabled
SW 9 ON
Enabled
SW 10 OFF
Disabled
SW 10 ON
Enabled
Position
Selection
Function/Description
Normally
Normally closed circuit – opens
1-2
closed (NC)
when BOND registers secure.
Normally
Normally open circuit – closes
2-3
open (NO)
when BOND registers secure.
Normally
Normally open circuit
1-2
open (NO)
– closes when door opens.
Normally
Normally closed circuit
2-3
closed (NC)
– opens when door opens.
1-2
Disabled
When enabled, allows unit to
be initiated from an external
source. (J1, Terminal 4)
2-3
Enabled
Position
Selection
Function/Description
LED
When enabled, LEDs
SW 1 ON
enabled
display lock status.
LED
SW 1 OFF
disabled
SW 2 – SW 9
N/A
Reset
SW 10 OFF
disabled
When enabled, restores
Magnalock firmware
Reset
to factory settings.
SW 10 ON
enabled
Function/Description
Time that the door must be pushed before
triggering the irrevocable alarm cycle. Set
the desired nuisance delay in seconds.
Set the desired irrevocable
alarm interval in seconds.
WARNING: a 30 second delay must be
approved by local code enforcement.
The expected time for a door closure
after manually bypassing (unlocking)
the system to exit or enter.
Set the desired bypass time in seconds.
When enabled, provides audible
indication after an alarm event.
When enabled, provides audible indication
when the bypass time has been exceeded.
When enabled, the system
automatically relocks 30 seconds
after an irrevocable alarm cycle.
When enabled, system starts
in the unlocked state.
When enabled, prevents irrevocable
alarm after bypass expiration. If SW7
is on, bypass expiration alarm repeats.
If SW7 is off, LED strobe flashes.
Factory Default
Normally closed
Normally open
Disabled
Factory Default
ON
Not used.
OFF
OFF
Factory Default
0 seconds
15 seconds
0 seconds
Disabled
Disabled
Disabled
Disabled
Disabled
7 of 12