Installing the strike
on the door
1
With the door closed, ALIGN the strike housing
with the template pins as indicated on the
strike housing. Ensure the strike housing is
pushed up snug against the template pins.
2
MARK seven strike housing mounting
hole locations (see Diagram 11).
3
REMOVE the strike housing from the door and the
template pins from the lock mounting bracket.
From the INSIDE
4
DRILL a level 3/8" diameter hole for the
sex bolt all the way through the door at
the strike mounting center mark.
5
FOR A HOLLOW METAL DOOR: DRILL six (6) #36
(0.107") holes through the inside skin of the door for
the strike housing mounting screws.
FOR A WOOD DOOR: DRILL six (6) #36 (0.107)" x 1/2"
deep holes for the strike housing mounting screws.
From the OUTSIDE
6
FOR A HOLLOW METAL DOOR: DRILL out the
3/8" diameter sex bolt hole to 1/2" diameter in the
outside skin of the door (see Diagram 12).
FOR A WOOD DOOR: DRILL out the
3/8" diameter sex bolt hole to 1/2"
diameter completely through door.
Secure the strike plate
assembly to the door
7
INSERT the sex bolt into the hole from the
outside of the door (see Diagram 13).
8
ATTACH the strike plate housing using six (6) 6-32 x
3/8" Phillips flat-head screws for METAL –OR– six (6)
#6 x 1/2" Phillips flat-head screws for WOOD door.
9
CRITICAL STEP: PLACE the tapered washer on the
strike assembly screw with the smaller diameter
surface of the washer facing against the back
of the strike plate, as shown in Diagram 14.
10
APPLY thread-lock compound (included)
to the strike assembly screw.
11
INSERT the strike assembly screw through the
strike housing and door and into the sex bolt.
12
CRITICAL STEP: TIGHTEN the screw into the sex
bolt using the 3/16" hex wrench. While tightening,
gently tap the head of the sex bolt using a rubber
mallet until the head sits flush with the door.
NOTE: To provide maximum door movement after
installation, the head of the strike assembly screw should be
approximately 0.025" (about the thickness of a paperclip)
below the surface of the strike as shown in Diagram 15.
NOTE: DEM680E detects door movement through a concealed
'patent pending' strike assembly. OVERTIGHTENING the strike
assembly screw will reduce door movement range and may cause
false alarms. DO NOT OVERTIGHTEN the strike assembly screw.
4 of 12
Diagram 11 Marking the
strike housing mounting hole
locations from the inside
Mark all seven (7) holes
Diagram 13 Securing the plate assembly to the door
STRIKE HOUSING
STRIKE PLATE
3/16" HEX KEY
STRIKE ASSEMBLY SCREW
Diagram 14 Strike assembly
installed – section view
Only hand tighten
strike assembly
screw
Strike
Assembly
Screw
Strike
Plate
Sex Bolt
Strike
Housing
Diagram 12 Drilling the sex
bolt hole from the outside
DOOR
TAPERED
WASHER
Metal Door: 6x 6-32 X 3/8" Self
Tapping Phillips Flat Head Screws
Wood Door: OOv #6 X 1/2" Type
A Phillips Flat Head Screws
Diagram 15 Strike assembly
installed – inside door
Approximate .025"
Tapered Washer
Orientation