Assa Abloy SECURITRON DEM680E Series Installation & Operating Instructions Manual page 6

Delayed egress magnalock with ecomag technology
Table of Contents

Advertisement

MAGNALOCK ELECTRICAL INSTALLATION
Pulling the wiring
NOTE: End-user and installer must comply
with fire and building codes.
1
PULL wires/cables through the wire feed-
through hole(s) drilled in the frame.
2
INSTALL the provided wall-
mounted switch if necessary.
Connecting the
final wiring
1
CONNECT the wires using Diagrams 24
through 28 as guides and as applicable.
NOTE: The positive terminal (+) and reference
voltage (VREF) are internally bussed to provide
a reference voltage for external control.
2
LOCATE the jumpers as shown in Diagram 29.
3
SET the jumpers for the desired
function using Table 1.
4
LOCATE the DIP-switches as
indicated in Diagram 30.
5
Select the desired Magnalock functions
using Table 2 and the desired delay-
egress functions using Table 3.
Diagram 26 Typical system wiring
DEM680E
Terminal Block
Header J1
Power
Supply
6 of 12
Diagram 24 Location of J1 and J4 terminals
Diagram 25 Terminal pin-out diagram
Diagram 27 Typical system wiring
with external initiate device
Power
Supply
Wall Mounted
Key Switch
External
Initiate
Device
(optional)
Dry Alarm
Contacts
Terminal Block
Header J1
Terminal Block
Header J4
DEM680E
Terminal Block
Header J1
Wall Mounted
Key Switch
Dry Alarm
Contacts
H3
Door Status
Bond Status
Diagram 28 Typical system
wiring with external controls
DEM680E
Power
Terminal Block
Supply
Header J1
"(+) and "VREF" Terminals are internally bussed to provide
reference (+) voltage external control use.
Input
Voltage
External
Controls
External
Alarm
Dry Alarm
Contacts