Intel GSU31 User Manual page 17

Integrated raid controller
Table of Contents

Advertisement

8. A screen prompt will ask which components (see below) you wish to install. Select the
following components and hit F10 to continue.
BKSTROSM.HAM
HTTP and Winsock Services
RAID Management Agents
The appropriate files are copied and the AUTOEXEC.NCF and STARTUP.NCF files are
modified as necessary.
Caution:
Once the product is installed, check for and remove any duplicate lines in STARTUP.NCF. For
example, NetWare 4.2 installations may insert an extra load line for the module PK411.NLM.
Remove the extra line.
9. After the installation is complete, reboot the server.
10. Load Support Pack 8a and reboot.
11. Installation of your GSU31 is now complete. Refer to subsequent chapters in this user's
manual for additional information.
NetWare 5
Note:
If you do not use the boot capability of the NetWare 5 CD-ROM, then replace step 2-5 below with
steps 2-4 of the NetWare 4.2 instructions above.
1. Insert the NetWare CD-ROM and reboot.
2. After booting, accept the license agreement. Then select Create a New Boot Partition.
3. When NetWare boots again, it will first format the newly created boot partition, and then start
loading files. During this initialization, you will see a white graphical NetWare logo screen.
4. It will eventually load a Welcome screen, asking you to verify the startup directory
(C:\NWSERVER). Hit Alt F10 to exit the installation. At the console, type Down. The
installation exits to the boot drive prompt.
5. Insert the GSU31 NetWare installation diskette created in
boot drive is C:, then run NWUPDATE.BAT. If your boot drive is other than C:, then create an
NWUPDATE subdirectory and copy all the files from A:\DRIVERS into the NWUPDATE
subdirectory.
6. Remove the diskette from the A: drive and reboot the server. After booting you will be asked
to accept the license agreement. Do so and then select Continue with Existing Partition. You
are now ready to install NetWare 5 on the Intel Integrated RAID volume.
7. Continue with the NetWare installation as normal by following the screen prompts. Select the
Block Storage OSM when prompted.
8. Reboot the server and install Service Pack 4 or higher. Once the server installation is
completed, reboot the server.
9. To install the Intel Integrated RAID software (run the Intel Integrated RAID setup) run
NWCONFIG.
10. Select Product Options, then Install product not listed. It will tell you that it is going to scan
the A: drive for installation scripts. Ensure the GSU31 NetWare Installation diskette is in the
floppy drive, hit Enter to continue.
Intel® Integrated RAID Controller GSU31 User's Manual Rev 1.0
Quick Start Instructions
Section 1.6
into the A: drive. If your
1-9

Advertisement

Table of Contents
loading

Table of Contents