Specifications For "Pt" Meters - Emerson Daniel PT Series Installation And Maintenance Instructions Manual

Liquid turbine meters
Table of Contents

Advertisement

(1) Above dimensions subject to change without notice.
(2) Weight is without preamplifier assembly. Add 4 lbs. for each preamplifier assembly.
1.2

Specifications for "PT" Meters

"PT" Meter, rim and blade type, when installed with meter tube and calibrated on water.
straightening sections and
Linearity:
3" and larger:
Repeatability:
±0.02% at any point throughout the extended minimum to extended maximum flow range
Pressure Drop:
At maximum flow of normal flow range on water 4 psi
Pressure Range:
ANSI 150-1500# depending upon size
Viscosity:
High viscosities will reduce flow range of meter. Consult Daniel Measurement engineers.
Pickup Coil:
Nominal open circuit peak to peak voltage output:
Minimum flow
Maximum flow
Table 1-2:
Item
Meter body
Flanges (slip on)
Suspension
Installation and maintenance instructions
±0.25% normal linearity
±0.5% over extended minimum to extended maximum flow range
±0.15% premium linearity
±0.10% premium + linearity
±0.07% premium ++ linearity
Materials of construction
Blade
4.0v
0.3v
Standard
304SS
Carbon steel
304SS
Dimensions and specifications of the meter
Rimmed
5.0v
0.1v
Optional
316SS
304SS or 316SS
316SS
3