Cal-Royal ES1520 Series Installation Instructions

Advertisement

Quick Links

ES1520 Series
CA L•R OYAL
Electric Strike Installation Instructions
PRODUCTS, INC .
The strike is polarity insensitive
Specifications
The ES1520 Series of electric strikes are designed for use with cylindrical locksets and accomodate latchbolts up to 9/16" throw.
The strikes can be configured to fail-safe or fail-secure on site.
Operating Voltage 12 / 24VDC
Dual Voltage:
Current Draw
300mA / 12VDC, 150mA / 24VDC
+ 14
F to+ 120
°
Operating Temperature
(-10
C to+ 49
°
Humidity 0% to 85% Non-condensing
Latch Throw 9/16" (15mm) maximum
Keeper Width 1 7/16" (36mm)
Static Strength 1500 lbs (680Kg)
Dynamic Strength 70 ft-lbs
250,000 cycles (UL tested)
Endurance
1,000,000 cycles (Factory tested)
Destructive Attack: Level 1
Line Security: Level 1
Performance Level
Standby Power: Level 1
Endurance: Level IV
Body
Latch
Model
Construction
Monitor
Zinc Alloy
ES1520
UL Requirements
• For Indoor Use Only.
• Wiring methods shall be in accordance with NFPA70.
• The ES1520 Series is intended to be used with UL Listed Exit Hardware.
• The ES1520 Series shall not impair the intended operation of an
emergency exit.
• The ES1520 Series shall not impair the operation of panic hardware
mounted on the door.
Wiring Diagrams
Dual Voltage {12V/24V)
For 12V
C Operation:
D
(Polarity Insensitive)
For 24V
C Operation:
D
(Polarity Insensiti
CAL-ROYAL
P R O D U C T S,
I N C. U.S. A.
F
°
C)
°
Latch
Frame
Throw
Hollow
9/16"
Metal
(15mm)
C
nt
rol
-- -
!
'-
1-
...
:J _____________ ;
nt
rol
......_ ___ c+-�
e)
! ______________ :
v
Cylindrical Knob Lockset
Strike Body
Face late
Kee er
J � �
e
ce
D
v
-
:
-
....
....
B
e
ce
D
v
+
:-
-
_
_
!
Cylindrical Le
er Lockset
v
N.C. for "Fail-Safe" Operation
N.O. for "Fail-Secure" Operation
DWG # ELG8011, P1/2 , 20220407