20. For fuel winter storage, FNM
®
additive. FNM
Take care of the engine storage room out of the boat or maintain the boat engine room dry and
free from salt vapor.
3.5.2 Operations to restore the engine after periods of inactivity
After a period of inactivity, it is necessary to carry out few maintenance interventions before starting
the engine again to ensure its efficiency and duration.
1. Verify the battery charge level conditions. Make sure that the battery voltage is greater than 12
Volt.
2. -Make sure that the electric contacts are intact and properly greased with basic grease. Assure
the correct electrical connections.
3. Carry out the engine electronic diagnosis at the first starting after a long period of inactivity.
4. -Check the oil level conditions, and if necessary, top up or replace with synthetic oil FNM
5W40.
5. Verify the clogging level and if necessary replace the oil filter.
6. Check the coolant level and if necessary top up. Drain the sea water circuits.
7. Verify and if necessary replace or clean the fuel filter.
8. Clean the air filter.
®
FNM
HPE Series
advises (for very cold storage) to use diesel fuel antifreeze
®
advises use of Bardahl
®
Diesel Antifreeze.
®
SAE
105